Spot-lights for eye surgery.

نویسنده

  • C R Kanagasundaram
چکیده

Although operating microscopes are readily available in ophthalmic operating theatres certain procedures are more conveniently done without them and some surgeons prefer spot-lights rather than the large shadow-free theatre lamps. Single or twin spot-lights, unlike the large theatre lamps, produce little reflection off such tissues as the cornea which could obscure details of structures behind. Spot-lights can also be placed at a more satisfactory angle than large theatre lamps. Some models of the Zeiss (Oberkochen) operating microscopes have twin larnps in supports which hold them obliquely in a fixed position where they illuminate the field of the microscope. These larnps provide a bright and evenly lit circle of illumination and make excellent spot-lights for eye surgery for those procedures where the microscope is not

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study

Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...

متن کامل

Merit function for the evaluation of color uniformity in the far field of LED spot lights

The scope of the present paper is the derivation of a merit function which predicts the visual perception of LED spot lights. The color uniformity level Usl is described by a linear regression function of the spatial color distribution in the far field. Hereby, the function is derived from four basic functions. They describe the color uniformity of spot lights through different features. The re...

متن کامل

Comparison of 2 wavefront-guided excimer lasers for myopic laser in situ keratomileusis: one-year results.

PURPOSE To compare laser in situ keratomileusis (LASIK) outcomes between 2 wavefront-guided excimer laser systems in the treatment of myopia. SETTING University eye clinic, Palo Alto, California, USA. DESIGN Prospective comparative case series. METHODS One eye of patients was treated with the Allegretto Wave Eye-Q system (small-spot scanning laser) and the fellow eye with the Visx Star Cu...

متن کامل

Approximating Real-World Luminaires with OpenGL Lights

Dynamic illumination in real-time applications using OpenGL is still usually done with the classical light forms of point lights, directional lights and spot lights. For applications simulating real-world scenes, e.g. architectural planning, finding parameter sets for these simple lights to match real-world luminaires is required for realistic work. This paper describes a simple approach to pro...

متن کامل

Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography

BACKGROUND/AIMS This case report aims to evaluate safety, efficacy and applicability of anterior surface imaging in a patient with forme fruste keratoconus (FFKC) based on a novel multi-spot, multicolor light-emitting-diode (LED) tear film-reflection imaging technology. CASE DESCRIPTION A 45-year-old male patient, clinically diagnosed with FFKC, with highly asymmetric manifestation between hi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 59 9  شماره 

صفحات  -

تاریخ انتشار 1975