The validity of wireless iButtons and thermistors for human skin temperature measurement.

نویسندگان

  • A D Harper Smith
  • D R Crabtree
  • J L J Bilzon
  • N P Walsh
چکیده

Skin temperature is a fundamental variable in human thermo-physiology, and yet skin temperature measurement remains impractical in most free-living, exercise and clinical settings, using currently available hard-wired methods. The purpose of this study was to compare wireless iButtons and hard-wired thermistors for human skin temperature measurement. In the first of two investigations, iButtons and thermistors monitored temperature in a controlled water bath (range: 10-40 degrees C) and were referenced against a certified, mercury thermometer. In the second investigation, eight healthy males completed three randomized trials (ambient temperature = 10 degrees C, 20 degrees C and 30 degrees C) while both devices recorded skin temperature at rest (in low and high wind velocities) and during cycle-ergometry exercise. The results are as follows. Investigation 1: both devices displayed very high validity correlation with the reference thermometer (r > 0.999). Prior to correction, the mean bias was +0.121 degrees C for iButtons and +0.045 degrees C for thermistors. Upon calibration correction the mean bias for iButtons and thermistors was not significantly different from zero bias. Interestingly, a typical error of the estimate of iButtons (0.043 degrees C) was 1.5 times less than that of thermistors (0.062 degrees C), demonstrating iButtons' lower random error. Investigation 2: the offset between iButton and thermistor readings was generally consistent across conditions; however, thermistor responses gave readings that were always closer to ambient temperature than those given by iButtons, suggesting potential thermistor drift towards environmental conditions. Mean temperature differences between iButtons and thermistors during resting trials ranged from 0.261 degrees C to 1.356 degrees C. Mean temperature differences between iButtons and thermistors during exercise were 0.989 degrees C (ambient temperature = 10 degrees C), 0.415 degrees C (ambient temperature = 20 degrees C) and 0.318 degrees C (ambient temperature = 30 degrees C). Observed error estimates were within the acceptable limits for the skin temperature method comparison, with typical errors <0.3 degrees C, correlation coefficients >0.9 and CV <1% under all conditions. These findings indicate that wireless iButtons provide a valid alternative for human skin temperature measurement during laboratory and field investigations particularly when skin temperature measurement using other currently available methods may prove problematic.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison between Conductive and Infrared Devices for Measuring Mean Skin Temperature at Rest, during Exercise in the Heat, and Recovery

PURPOSE Skin temperature assessment has historically been undertaken with conductive devices affixed to the skin. With the development of technology, infrared devices are increasingly utilised in the measurement of skin temperature. Therefore, our purpose was to evaluate the agreement between four skin temperature devices at rest, during exercise in the heat, and recovery. METHODS Mean skin t...

متن کامل

Evaluation of wireless determination of skin temperature using iButtons.

Measurements of skin temperatures are often complicated because of the use of wired sensors. This is so in field studies, but also holds for many laboratory conditions. This article describes a wireless temperature system for human skin temperature measurements, i.e. the Thermochron iButton DS1291H. The study deals with validation of the iButton and its application on the human skin, and descri...

متن کامل

Reliability and validity of skin temperature measurement by telemetry thermistors and a thermal camera during exercise in the heat.

New technologies afford convenient modalities for skin temperature (TSKIN) measurement, notably involving wireless telemetry and non-contact infrared thermometry. The purpose of this study was to investigate the validity and reliability of skin temperature measurements using a telemetry thermistor system (TT) and thermal camera (TC) during exercise in a hot environment. Each system was compared...

متن کامل

Supraclavicular Skin Temperature as a Measure of 18F-FDG Uptake by BAT in Human Subjects

BACKGROUND Brown adipose tissue (BAT) has emerged as a novel player in energy homeostasis in humans and is considered a potential new target for combating obesity and related diseases. The current 'gold standard' for quantification of BAT volume and activity is cold-induced 18F-FDG uptake in BAT. However, use of this technique is limited by cost and radiation exposure. Given the fact that BAT i...

متن کامل

A New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System

Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physiological measurement

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 2010