Measurement of ocular surface protection under natural blink conditions
نویسندگان
چکیده
PURPOSE To evaluate a new method of measuring ocular exposure in the context of a natural blink pattern through analysis of the variables tear film breakup time (TFBUT), interblink interval (IBI), and tear film breakup area (BUA). METHODS The traditional methodology (Forced-Stare [FS]) measures TFBUT and IBI separately. TFBUT is measured under forced-stare conditions by an examiner using a stopwatch, while IBI is measured as the subject watches television. The new methodology (video capture manual analysis [VCMA]) involves retrospective analysis of video data of fluorescein-stained eyes taken through a slit lamp while the subject watches television, and provides TFBUT and BUA for each IBI during the 1-minute video under natural blink conditions. The FS and VCMA methods were directly compared in the same set of dry-eye subjects. The VCMA method was evaluated for the ability to discriminate between dry-eye subjects and normal subjects. The VCMA method was further evaluated in the dry eye subjects for the ability to detect a treatment effect before, and 10 minutes after, bilateral instillation of an artificial tear solution. RESULTS Ten normal subjects and 17 dry-eye subjects were studied. In the dry-eye subjects, the two methods differed with respect to mean TFBUTs (5.82 seconds, FS; 3.98 seconds, VCMA; P = 0.002). The FS variables alone (TFBUT, IBI) were not able to successfully distinguish between the dry-eye and normal subjects, whereas the additional VCMA variables, both derived and observed (BUA, BUA/IBI, breakup rate), were able to successfully distinguish between the dry-eye and normal subjects in a statistically significant fashion. TFBUT (P = 0.034) and BUA/IBI (P = 0.001) were able to distinguish the treatment effect of artificial tears in dry-eye subjects. CONCLUSION The VCMA methodology provides a clinically relevant analysis of tear film stability measured in the context of a natural blink pattern.
منابع مشابه
Relationship between Corneal Sensation, Blinking, and Tear Film Quality.
PURPOSE To examine the possible role of corneal sensitivity and tear film quality in triggering a blink by investigating the relationship between blink rate, central corneal sensitivity threshold (CST), ocular surface temperature (OST), tear meniscus height (TMH), tear film quality (noninvasive tear break-up time [NIBUT]), and tear film lipid pattern under normal conditions. METHODS Forty-two...
متن کاملValidation and verification of the OPI 2.0 System
PURPOSE The Ocular Protection Index (OPI) 2.0 System was developed to evaluate ocular surface protection under a natural blink pattern and normal visual conditions. The OPI 2.0 System implements fully automated software algorithms which provide a real-time measurement of corneal exposure (breakup area) for each interblink interval during a 1-minute video. Utilizing this method, the mean breakup...
متن کاملThe effects of increasing ocular surface stimulation on blinking and sensation.
PURPOSE The purpose of this study was to determine how increasing ocular surface stimulation affected blinking and sensation, while controlling task concentration. METHODS Ten healthy subjects concentrated on a task while a custom pneumatic device generated air flow toward the central cornea. Six flow rates (FRs) were randomly presented three times each and subjects used visual analog scales ...
متن کاملSynthesis of nanocomposite based on Semnan natural zeolite for photocatalytic degradation of tetracycline under visible light
This study investigated the photocatalytic behaviors for the nanocomposite of TiO2 P25 and Semnan natural zeolite in the decomposition of tetracycline under visible light in an aqueous solution. The structural features of the composite were investigated by a series of complementary techniques that included X-ray diffractometer (XRD), Fourier transform infrared spectroscopy (FTIR), scanning elec...
متن کاملA Model for the Tear Film and Ocular Surface Temperature for Partial Blinks.
In this paper, we investigate the dynamics of tear film and the associated temperature variation for partial blinks. We investigate the mechanism of fluid supply during partial blink cycles, and compare the film thickness with observation in vivo. We find that varying the thickness of the fluid layer beneath the moving upper lid improves the agreement for the in vivo measurement of tear film th...
متن کامل