Vision measurement is the basis for the study and standardization of visual sciences. Measurement of visual acuity has great value for research and for clinical practice. This paper (1) reviews the fundamental concepts to understand visual sense and the measuring units; (2) presents the fundamental limits to visual performance and the principles of aberration measurement of the eye; and (3) discusses methods for measuring and classifying vision with new technologies.
منابع مشابه
Clinical validation of a computerized psychophysical test for color vision and contrast sensitivity
Purpose: To determine the reliability of TwoDocs computerized test for the evaluation of color vision and contrast sensitivity in normal adults. Methods: Thirty normal volunteers aged from 20 to 30 years (mean 23.3 years) had their color vision and contrast sensitivity tested by a new computerized test (TwoDocs test). Informed consent was obtained from all participants before testing. Inclusion...
متن کامل07 Psico-inglês 22-1.pmd
Organic solvents are neurotoxic substances that can cause damaging effects in the visual system. Occupational exposure to these substances is common because they are used in a wide variety of activities. These effects can be quantified by specific psychophysical tests. The most commonly used tests for color vision assessment are arrangement tests, such as the Lanthony Panel D-15 desaturated tes...
متن کاملPsychophysical Calibration of Mobile Touch-Screens for Vision Testing in the Field.
The now ubiquitous nature of touch-screen displays in cell phones and tablet computers makes them an attractive option for vision testing outside of the laboratory or clinic. Accurate measurement of parameters such as contrast sensitivity, however, requires precise control of absolute and relative screen luminances. The nonlinearity of the display response ("gamma") can be measured or checked u...
متن کاملThe value of preoperative tests in the selection of blind patients for a permanent microelectronic implant.
PURPOSE To determine the best candidates (ie, those requiring lowest current levels delivered to the retina to elicit visual perceptions) for long-term implantation of a microelectronic retinal implant through a series of preoperative visual, psychophysical, and electrophysiological tests. METHODS This study protocol was granted an investigational device exemption by the Food and Drug Adminis...
متن کاملClinical Tests of Ultra-Low Vision Used to Evaluate Rudimentary Visual Perceptions Enabled by the BrainPort Vision Device.
PURPOSE We evaluated whether existing ultra-low vision tests are suitable for measuring outcomes using sensory substitution. The BrainPort is a vision assist device coupling a live video feed with an electrotactile tongue display, allowing a user to gain information about their surroundings. METHODS We enrolled 30 adult subjects (age range 22-74) divided into two groups. Our blind group inclu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 71 1 شماره
صفحات -
تاریخ انتشار 2008