Tip-sample distance control using photothermal actuation of a small cantilever for high-speed atomic force microscopy.
نویسندگان
چکیده
We have applied photothermal bending of a cantilever induced by an intensity-modulated infrared laser to control the tip-surface distance in atomic force microscopy. The slow response of the photothermal expansion effect is eliminated by inverse transfer function compensation. By regulating the laser power and regulating the cantilever deflection, the tip-sample distance is controlled; this enables much faster imaging than that in the conventional piezoactuator-based z scanners because of the considerably higher resonant frequency of small cantilevers. Using this control together with other devices optimized for high-speed scanning, video-rate imaging of protein molecules in liquids is achieved.
منابع مشابه
Constant tip-surface distance with atomic force microscopy via quality factor feedback.
The atomic force microscope (AFM) is a powerful and widely used instrument to image topography and measure forces at the micrometer and nanometer length scale. Because of the high degree of operating accuracy required of the instrument, small thermal and mechanical drifts of the cantilever and piezoactuator systems hamper measurements as the AFM tip drifts spatially relative to the sample surfa...
متن کاملPhotothermal cantilever actuation for fast single-molecule force spectroscopy.
Photothermal cantilever excitation provides a fast and easy to implement means to control the deflection of standard atomic force microscopy cantilevers. Minute heat pulses yield deflections on the order of several tens of nanometers or when the deflection is kept constant, forces of several hundreds of piconewton can be applied. In our case these pulses resulted in less than 1 K temperature ch...
متن کاملAtomic-resolution imaging in liquid by frequency modulation atomic force microscopy using small cantilevers with megahertz-order resonance frequencies.
In this study, we have investigated the performance of liquid-environment FM-AFM with various cantilevers having different dimensions from theoretical and experimental aspects. The results show that reduction of the cantilever dimensions provides improvement in the minimum detectable force as long as the tip height is sufficiently long compared with the width of the cantilever. However, we also...
متن کاملDirect tip-position control using magnetic actuation for achieving fast scanning in tapping mode atomic force microscopy
This article presents the development of a faster control loop for oscillation amplitude regulation in tapping mode operation of atomic force microscopy. Two techniques in relation to actuation and measurement are developed, that together significantly increase the bandwidth of the control loop. Firstly, magnetic actuation is employed to directly control the tip position of the cantilever to im...
متن کاملSqueeze Film Air Damping in Tapping Mode Atomic Force Microscopy
In dynamic plowing lithography, the sample surface is indented using a vibrating tip in tapping mode atomic force microscopy. During writing, the gap between the cantilever and the sample surface is very small, usually on the order of micrometers. High vibration frequency and small distance induce squeeze film air damping from the air in the gap. This damping can cause variations in the cantile...