In-vitro comparison of 4 large-volume nebulizers in 8 hours of continuous nebulization.
نویسندگان
چکیده
BACKGROUND Continuous albuterol nebulization has become the standard of care for patients with status asthmaticus. Predictable albuterol delivery is paramount for effective therapy. We compared the aerosol characteristics, solution output, and albuterol output of 4 brands of large-volume nebulizer. METHODS We studied 6 units of the following nebulizer brands: AirLife Misty Finity (Cardinal Health), Flo-Mist (Smith's Medical), Heart (WestMed), and Hope (B&B Medical Technologies). All the nebulizers were operated according to the manufacturers' recommendations and connected to 180-cm of flexible corrugated tubing. We diluted 80 mg of albuterol sulfate nebulizer solution in saline solution, per the manufacturer's recommendations (admixture required to deliver 10 mg/h). Solution output, solution retained in the tubing, reservoir albuterol concentration, and albuterol output were determined hourly for 8 hours. The ambient and aerosol temperatures were recorded every 30 minutes. The target outputs were ± 20% of the manufacturer's specification. Aerosol characteristics were determined via cascade impaction, with aerosol collected between 60 and 70 min of operation. RESULTS All the aerosols had an adequate size for pulmonary deposition. The increase in reservoir albuterol concentration was < 20% for the first 4 hours. There were no significant differences in achieving the target albuterol output, but none of the nebulizers achieved the target albuterol output during the 1st hour. Albuterol output was similar between the nebulizers for the first 5 hours. There were no differences in reaching the target solution output. The Misty Finity and Hope had a solution output consistent with the manufacturers' specifications. The amount of solution retained in the tubing was greatest with the Heart (23%); other nebulizers' tubing-retained-solution ranged from 6-9%. Albuterol output corrected for the tubing-retained solution rendered similar results. Aerosol temperature decreased with aerosol production and increased in the corrugated tubing, but was below the ambient temperature at the patient interface. CONCLUSIONS The tested nebulizers had similar performance during the first 5 hours. The nebulizer solution might need to be replaced if treatment is planned for longer period. The Misty Finity and Hope nebulizers had a more consistent solution output.
منابع مشابه
Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.
BACKGROUND Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METH...
متن کاملIn-Vitro Comparison of Six Continuous Nebulizers*
BACKGROUND: Continuous nebulization has become popular for treating patients with severe reversible airway disease. Continuous nebulization therapy has been shown to be safe, effective, and labor efficient as compared to other traditional medication aerosol treatments 1-11 . Although numerous studies have been done evaluating the clinically efficacy of continuous nebulization, little work has b...
متن کاملContinuous nebulization therapy for asthma with aerosols of b2 agonists
Background: Various studies have demonstrated the benefits of continuous nebulization therapy for delivering aerosols of the b2 agonists such as terbutaline sulfate or albuterol sulfate to patients with severe asthma and/or impending respiratory failure. Objective: The purpose of this investigation was to explicate the operational factors associated with the use of nebulizers for extended aeros...
متن کاملAlbuterol delivery in an in vitro pediatric ventilator lung model: comparison of jet, ultrasonic, and mesh nebulizers.
OBJECTIVE To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN In vitro, laboratory study. SETTING Research laboratory of a university hospital. INTERVENTIONS Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested ...
متن کاملContinuous nebulization therapy for asthma with aerosols of beta2 agonists.
BACKGROUND Various studies have demonstrated the benefits of continuous nebulization therapy for delivering aerosols of the beta2 agonists such as terbutaline sulfate or albuterol sulfate to patients with severe asthma and/or impending respiratory failure. OBJECTIVE The purpose of this investigation was to explicate the operational factors associated with the use of nebulizers for extended ae...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 55 12 شماره
صفحات -
تاریخ انتشار 2010