99m Tc-labelled serum albumin in cardiac output and blood volume studies.
نویسندگان
چکیده
The use of human serum albumin labelled with iodine-131 (RIHSA) as the radioactive indicator in the measurement of cardiac output by the external counting technique is not ideal since the emission characteristics, physical half-life, and physiological fate restrict the amount that can be administered. A more suitable material, especially because of the short physical half-life of the isotope involved, is albumin labelled with technetium-99m. This communication describes a simple three-stage process for the preparation of such a complex which was then tested in subjects with no impairment of cardiac performance for its suitability in assays of cardiac output by the external counting method. Values were within the same range as those obtained with RIHSA in comparable subjects. Blood volumes estimated with 9"9Tc-albumin were within the limits of physiological variation of values derived with RIHSA in the same subjects. Serial blood samplings and urine collection during a period of 24 hours after administration showed that the preparation was lost continuously from the circulation at a more rapid rate than RIHSA. The greatest loss was in the first few hours when most of the urinary excretion of the isotope occurred. Comparison of the present data with published results using an alternative preparation suggests that our product may be more stable. Of the various methods available for the measurement of cardiac output, the external counting technique using a gamma-emitting isotope (Huff, Feller, Judd, and Bogardus, 1955; Veall and Vetter, 1958) is probably the least traumatic as far as the patient is concerned. Disturbance is minimal and, in particular, there is no requirement for catheterization of the heart or great vessels as is the case with the Fick and dye dilution methods. In general, '311-labelled human serum albumin (RIHSA) is used as the indicator but this material is not ideal since the emission characteristics restrict the amount that can be administered and the physical half-life and physiological fate leave a high circulating residuum in serial assays. Technetium-99m is potentially a better isotope as the emission characteristics permit more activity to be given and the short physical half-life contributes to a lower residuum. However, a prerequisite of the external counting method is the need for the indicator to remain intact in the circulation for at least 10 to 15 minutes after administration so that samples may be withdrawn for blood volume assay. To meet this condition the isotope must be combined to a relatively stable …
منابع مشابه
Quantification of right-to-left shunt with (99m)Tc-labelled albumin macroaggregates and 100% oxygen in patients with hereditary haemorrhagic telangiectasia.
Pulmonary arteriovenous malformations (PAVMs) are often associated with hereditary haemorrhagic telangiectasia (HHT). The quantification of right-to-left shunts in patients with PAVMs is important in diagnosis and follow up. Traditionally, this shunt is measured by the 100% oxygen method, in which the value for the arteriovenous difference in oxygen content, Cao(2)-CVO(2) (where Cao(2) is the o...
متن کاملAbnormal left ventricular relaxation in hypertensive patients.
1. The maximum rates of left ventricular ejection and filling were derived (Fourier analysis) from the left ventricular volume curve (99m technetium-human serum albumin gated blood pool studies) in 12 normotensive subjects and 15 hypertensive patients of matched age groups. 2. Average values of cardiac output, ejection fraction, heart rate and left ventricular ejection rate were not significant...
متن کاملPreparation of human serum albumin microspheres (MSA) kit for lung imaging in Iran [Persian]
Radiolabeled Microspheres of human serum albumin (MSA) is of great importance in the analysis of regional lung perfusion. Preparation of MSA kit has been installed in our Division recently is carried out in two stages: 1. Production of albumin sphere particles with suitable sizes by using the spinning disk technique. 2. Formulation of MSA as a radiopharmacutical kit. So it can be labelled...
متن کاملOn-Site Preparation of Tc-99m Albumin for Clinical Application
WANG, Y.F., CHUANG, M.H., CHIU, J.S., CHAM, T.M. and CHUNG, M.I. On-Site Preparation of Technetium-99m Labeled Human Serum Albumin for Clinical Application. Tohoku J. Exp. Med., 2007, 211 (4), 379-385 ── Technetium-99m labeled human serum albumin (Tc-99m HSA) is an important radiopharmaceutical for clinical applications, such as cardiac function tests or protein-losing gastroenteropathy assessm...
متن کاملTechnetium-99m-Labeled Autologous Serum Albumin: A Personal-Exclusive Source of Serum Component
Technetium-99m human serum albumin ((99m)Tc-HSA) is an important radiopharmaceutical required in nuclear medicine studies. However, the risk of transfusion-transmitted infection remains a major safety concern. Autopreparation of serum component acquired from patient provides a "personal-exclusive" source for radiolabeling. This paper is to evaluate the practicality of on-site elusion and subseq...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 26 4 شماره
صفحات -
تاریخ انتشار 1971