Comparison of single-photon emission computed tomography with [123I]iodoamphetamine and xenon-enhanced computed tomography for assessing regional cerebral blood flow.
نویسندگان
چکیده
Regional CBF (rCBF) images obtained from xenon-enhanced computed tomography (XeCT) and single-photon emission computed tomography (SPECT) with N-isopropyl-p-[123I]iodoamphetamine (IMP) done with a rotating gamma-camera were compared in nine patients. Both XeCT and SPECT/IMP demonstrated flow abnormalities at all sites of infarction identified by CT, while detecting reduced rCBF in areas normal by CT in eight of the nine patients. All areas that were abnormal on XeCT were abnormal on the comparable SPECT/IMP images. The major advantages of XeCT are its greater resolution and potential for noninvasive quantitation of rCBF, while the major advantage of SPECT/IMP is its visualization of the entire brain on transverse, coronal, and sagittal sections.
منابع مشابه
Critical CerebralBlood Flow Thresholds Studied by SPECT Using Xenon-133 and Iodine-123 lodoamphetamine
activity and blood flow was first observed during carotid endarterectomy by electroencephalogram (EEG) mon itoring and xenon-133 (†̃33Xe) intracarotid injection techniques. These studies have demonstrated a thresh old of 17—18ml/100 g/min for EEG flattening (1—4). Since then many experimental studies on focal ischemia have developed a concept of―ischemicflow thresholds― (5—8). In exp...
متن کاملDetection of misery perfusion with split-dose 123I-iodoamphetamine single-photon emission computed tomography in patients with carotid occlusive diseases.
BACKGROUND AND PURPOSE Patients with carotid occlusive disease and stage 2 cerebral hemodynamic failure, characterized by an increased oxygen extraction fraction (OEF) as measured by positron emission tomography (PET) and otherwise known as misery perfusion, have a high risk of cerebral ischemia and subsequent stroke. In clinical practice, the detection of patients with misery perfusion through...
متن کاملQuantitative assessment of cerebral blood volume by single-photon emission computed tomography.
We implemented a technique for measuring regional cerebral blood volume using single-photon emission computed tomography and in vivo technetium-99m-labeled red blood cells and then evaluated it in nine normal human volunteers (controls) and seven patients with bilateral occlusion or severe stenosis of the internal carotid artery. We also measured regional cerebral blood flow using single-photon...
متن کاملAbnormal cerebral blood flow in methamphetamine abusers assessed by brain perfusion single emission computed tomography
Introduction:Amphetamines are central nervous system (CNS) stimulant substances and amphetamine abuse is considered a growing problem in our country. Previous studies revealed destructive effects of amphetamines on metabolism, perfusion and structure of brain. The aim of current study was evaluating regional cerebral blood flow (rCBF) disturbances in methamphetamine (MA) abuser...
متن کاملThallium-201 diethyldithiocarbamate: an alternative to iodine-123 N-isopropyl-p-iodoamphetamine.
The study of cerebral blood flow by single photon emission computed tomography (SPECT) requires lipophilic radiopharmaceuticals. The high cost and limited availability of N-isopropyl-p-[I-123]-iodoamphetamine ( [123I]IMP) led us to search for alternatives. Following our recent development of thallium-201 diethyldithiocarbamate ( [201TI]DDC), we have compared the brain uptake of [123I]IMP and [2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism
دوره 6 6 شماره
صفحات -
تاریخ انتشار 1986