Assessment of nodal target definition and dosimetry using three different techniques: implications for re-defining the optimal pelvic field in endometrial cancer
نویسندگان
چکیده
PURPOSES 1. To determine the optimal pelvic nodal clinical target volume for post-operative treatment of endometrial cancer. 2. To compare the DVH of different treatment planning techniques applied to this new CTV and the surrounding tissues. METHODS AND MATERIALS Based on the literature, we selected a methodology to delineate nodal target volume to define a NEW-CTV and NEW-PTV. Conventional 2D fields, 3D fields based on anatomic guidelines per RTOG 0418, 3D fields based on our guidelines, and IMRT based on our guidelines were assessed for coverage of NEW-CTV, NEW-PTV, and surrounding structures. CT scans of 10 patients with gynecologic malignancies after TAH/BSO were used. DVHs were compared. RESULTS For NEW-PTV, mean V45Gy were 50% and 69% for 2D and RTOG 0418-3DCRT vs. 98% and 97% for NEW-3DCRT and NEW-IMRT (p < 0.0009). Mean V45Gy small bowel were 24% and 20% for 2D and RTOG 0418-3DCRT, increased to 32% with NEW-3DCRT, and decreased to 14% with IMRT (p = 0.005, 0.138, 0.002). Mean V45Gy rectum were 26%, 35%, and 52% for 2D, RTOG 0418-3DCRT, and NEW-3DCRT, and decreased to 26% with NEW-IMRT (p < 0.05). Mean V45Gy bladder were 83%, 51%, and 73% for 2D, RTOG 0418-3DCRT, and NEW-3DCRT, and decreased to 30% with NEW-IMRT (p < 0.002). CONCLUSIONS Conventional 2D and RTOG 0418-based 3DCRT plans cover only a fraction of our comprehensive PTV. A 3DCRT plan covers this PTV with high doses to normal tissues, whereas IMRT covers the PTV while delivering lower normal tissue doses. Re-consideration of what specifically the pelvic target encompasses is warranted.
منابع مشابه
Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT
Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...
متن کاملComparison of three different techniques in parotid gland tumors using three dimensional conformal radiation therapy
Introduction: Background: Radiotherapy of parotid tumors is achieved by different radiotherapy techniques. So they deliver the dose to organs at risk such as contralateral parotid, temporal lobe & spinal cord. The consequences of high dose to OARs are xerostomia, Temporal lobe necrosis and loss of hearing. Purpose: The aim of this study was to compare different treatment tech...
متن کاملDetermining rectal dose through cervix cancer radiotherapy by 9 MV photon beam using TLD and XR type T GAFCHROMIC® Film
Background: The goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. Materials and Methods: The study was carried out using a Nepton 10...
متن کاملDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
متن کاملOut-of-field photon dosimetry study between 3-D conformal and intensity modulated radiation therapy in the management of prostate cancer
Background: The present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (TPS), Oncentra, for three-dimensional conformal radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) treatment techniques from Elekta Synergy medical linear accelerator. Materials and Methods: Accuracy of individual out-of-field dose components was...
متن کامل