Echocardiographic Assessment of Left Ventricular Function in Healthy Horses and in Horses with Heart Disease Using Pulsed‐Wave Tissue Doppler Imaging

نویسندگان

  • T.R. Koenig
  • K.J. Mitchell
  • C.C. Schwarzwald
چکیده

BACKGROUND Assessment of left ventricular (LV) function by tissue Doppler imaging (TDI) is not well established in horses with heart disease. OBJECTIVES To describe the use of pulsed-wave (PW) TDI for the assessment of LV function, establish reference intervals, investigate effects of mitral regurgitation (MR), aortic regurgitation (AR), and primary myocardial disease (MD), and provide proof of concept for the use of PW TDI in Warmblood horses with heart disease. ANIMALS Thirty healthy horses, 38 horses with MR, 25 with AR, 8 with MD. METHODS Echocardiograms were retrospectively analyzed. Reference intervals were calculated. PW TDI indices of healthy horses and horses with MR, AR, and MD were compared by one-way ANOVA and Dunnett's test. RESULTS A complete set of PW TDI variables could be obtained in 94 of 101 horses. Variables corresponding to isovolumic intervals were most difficult to measure. Valvular regurgitation influenced variables describing isovolumic contraction and ejection. Horses with MD had significantly shortened ETm (-118.5 [-154.1 to -82.9] ms; mean difference [95% CI of difference of means]), increased PEPm /ETm (0.11 [0.05 to 0.17]), prolonged IMPm (0.28 [0.18 to 0.37]), increased S1 (8.9 [5.2 to 12.6] cm/s), and decreased E1 (-2.6 [-4.7 to -0.5] cm/s), Em (-14.2 [-19.9 to -8.5] cm/s), and Em /Am ratio (-1.6 [-2.6 to -0.6]). CONCLUSIONS AND CLINICAL IMPORTANCE Pulsed-wave TDI might be useful for detection of LV dysfunction in horses with primary MD. The clinical value of TDI in horses with MR and AR remains uncertain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran

Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...

متن کامل

Normal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran

The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...

متن کامل

Echocardiographic Evaluation of left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation

Extended abstract Echocardiographic Evaluation of Left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation Cardiovascular disease (CVD) is an important, leading cause of mortality and morbidity in patients with chronic kidney disease (CKD) as well as in renal transplant recipients. Cardiovascular complications become more important in children because of the i...

متن کامل

بررسی اثر کاهش حجم بر روی پارامترهای دیاستولیک اکو کاردیوگرافی در بیماران همودیالیزی

Background: Cardiovascular problems including arterial hypertension, coronary artery diseases, congestive heart failure are prevalent among chronic hemodialyzed patients. Ultrafiltration of hemodialyzed patient's serum, which culminating in intravascular volume reduction, is frequently used during hemodialysis. One of the restrictions of the echocardiographic evaluation of the diastolic heart f...

متن کامل

Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -

تاریخ انتشار 2017