Sensitivity of Five Rapid HIV Tests on Oral Fluid or Finger-Stick Whole Blood: A Real-Time Comparison in a Healthcare Setting

نویسندگان

  • Juliette Pavie
  • Anne Rachline
  • Bénédicte Loze
  • Laurence Niedbalski
  • Constance Delaugerre
  • Eric Laforgerie
  • Jean-Christophe Plantier
  • Willy Rozenbaum
  • Sylvie Chevret
  • Jean-Michel Molina
  • François Simon
چکیده

BACKGROUND Health authorities in several countries recently recommended the expansion of human immunodeficiency virus (HIV) antibody testing, including the use of rapid tests. Several HIV rapid tests are now licensed in Europe but their sensitivity on total blood and/or oral fluid in routine healthcare settings is not known. METHODS AND FINDINGS 200 adults with documented HIV-1 (n=194) or HIV-2 infection (n=6) were prospectively screened with five HIV rapid tests using either oral fluid (OF) or finger-stick whole blood (FSB). The OraQuick Advance rapid HIV1/2 was first applied to OF and then to FSB, while the other tests were applied to FSB, in the following order: Vikia HIV 1/2, Determine HIV 1-2, Determine HIV-1/2 Ag/Ab Combo and INSTI HIV-1/HIV-2. Tests negative on FSB were repeated on paired serum samples. Twenty randomly selected HIV-seronegative subjects served as controls, and the results were read blindly. Most patients had HIV-1 subtype B infection (63.3%) and most were on antiretroviral therapy (68.5%). Sensitivity was 86.5%, 94.5%, 98.5%, 94.9%, 95.8% and 99% respectively, with OraQuick OF, OraQuick FSB, Vikia, Determine, Determine Ag/Ab Combo and INSTI (p<0.0001). OraQuick was less sensitive on OF than on FSB (p=0.008). Among the six patients with three or more negative tests, two had recent HIV infection and four patients on antiretroviral therapy had undetectable plasma viral load. When patients positive in all the tests were compared with patients who had at least one negative test, only a plasma HIV RNA level<200 cp/ml was significantly associated with a false-negative result (p=0.009). When the 33 rapid tests negative on FSB were repeated on serum, all but six (5 negative with OraQuick, 1 with INSTI) were positive. The sensitivity of OraQuick, Determine and Determine Ag/Ab Combo was significantly better on serum than on FSB (97.5%, p=0.04; 100%, p=0.004; and 100%, p=0.02, respectively). CONCLUSION When evaluated in a healthcare setting, rapid HIV tests were less sensitive on oral fluid than on finger-stick whole blood and less sensitive on finger-stick whole blood than on serum.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

False-positive oral fluid rapid HIV tests--New York City, 2005-2008.

The New York City Department of Health and Mental Hygiene (NYC DOHMH) operates 10 sexually transmitted disease (STD) walk-in clinics offering various free services, including confidential or anonymous testing for human immunodeficiency virus (HIV). In January 2004, the STD clinics introduced on-site rapid HIV testing of finger-stick whole-blood specimens using the OraQuick(R) brand test (OraSur...

متن کامل

False-negative HIV tests using oral fluid tests in children taking antiretroviral therapy from Harare, Zimbabwe

INTRODUCTION Rapid diagnostic tests (RDT) for HIV infection have high sensitivity and specificity, but in the setting of longstanding antiretroviral therapy (ART), can give false results that can lead to misinterpretation, confusion and inadequate management. The objective of this study was to evaluate the proportion of falsely negative results of a RDT performed on oral fluid in HIV-infected c...

متن کامل

Evaluation of Diagnostic Accuracy, Feasibility and Client Preference for Rapid Oral Fluid-Based Diagnosis of HIV Infection in Rural India

BACKGROUND Oral fluid-based rapid tests are promising for improving HIV diagnosis and screening. However, recent reports from the United States of false-positive results with the oral OraQuick ADVANCE HIV1/2 test have raised concerns about their performance in routine practice. We report a field evaluation of the diagnostic accuracy, client preference, and feasibility for the oral fluid-based O...

متن کامل

Impact of Round-the-Clock, Rapid Oral Fluid HIV Testing of Women in Labor in Rural India

BACKGROUND Testing pregnant women for HIV at the time of labor and delivery is the last opportunity for prevention of mother-to-child HIV transmission (PMTCT) measures, particularly in settings where women do not receive adequate antenatal care. However, HIV testing and counseling of pregnant women in labor is a challenge, especially in resource-constrained settings. In India, many rural women ...

متن کامل

Investigation of False Positive Results with an Oral Fluid Rapid HIV-1/2 Antibody Test

BACKGROUND In March 2004, the OraQuick rapid HIV antibody test became the first rapid HIV test approved by the US Food and Drug Administration for use on oral fluid specimens. Test results are available in 20 minutes, and the oral fluid test is non-invasive. From August 2004-June 2005, we investigated a sudden increase in false-positive results occurring in a performance study of OraQuick oral-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2010