Reproducibility of cephalometric landmarks on conventional film, hardcopy, and monitor-displayed images obtained by the storage phosphor technique.

نویسندگان

  • W Geelen
  • A Wenzel
  • E Gotfredsen
  • M Kruger
  • L G Hansson
چکیده

The aim of the present study was to evaluate and compare the reproducibility of cephalometric landmarks on (1) conventional films, and images acquired by storage phosphor digital radiography both on (2) hardcopy and (3) monitor-displayed versions. The material consisted of 19 cephalograms for each image modality. The phosphor plates were scanned in an image reader and the 10-bit normalized, raw data digital images were converted to 8-bit TIFF images for PC monitor-display. The digital hardcopies were produced in a laser printer. Six observers were asked to record 21 cephalometric landmarks on each conventional film, hardcopy, and monitor-displayed image. For the films and hardcopies, the landmark co-ordinates were recorded via a digitizing tablet. For the monitor-displayed images, the co-ordinates were recorded directly from the monitor using a dedicated Windows-based cephalometric program. Reproducibility was defined as an observer's deviation (in mm) from the mean between all observers. Differences between the image modalities and between the observers were tested by two-way analysis of variance for each landmark. There was a statistically significant difference between the reproducibility of film, hardcopy and monitor-displayed images in 11 of the 21 landmarks. There was no unequivocal trend that one modality was always the best. For a full cephalometric recording (the sum of all 21 landmarks), the monitor-displayed images (mean = 25.3 mm) had a lower precision than film (P < 0.005) and hard-copy (P < 0.02). There was no significant difference between film (mean = 21.8 mm) and hardcopy (mean = 22.8 mm). The lower reproducibility seen for the monitor-displayed images is most probably of little clinical significance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه دقت تصاویر رادیوگرافی

Statement of Problem: Computer Sciences, in radiology, like other fields, is of high importance. It should also be noted that the accuracy of the technique and work conditions affects the radiographs information considerably. There for, in order to get more accurate diagnostic information, it seems necessary to investigate different digitized radiographic techniques and to compare them with the...

متن کامل

Accuracy of cephalometric landmarks on monitor-displayed radiographs with and without image emboss enhancement.

The aim of this study was to evaluate the accuracy of some commonly used cephalometric landmarks of monitor-displayed images with and without image emboss enhancement. The following null hypothesis was tested: there is no improvement in landmark detection accuracy between monitor-displayed images, with and without image embossing enhancement. Forty lateral cephalometric radiographs, taken from ...

متن کامل

مقایسه تفاوت لندمارک های آناتومیک دو تکنیک رادیوگرافی لترال سفالومتری دیجیتال و معمولی به روش ترسیم دستی در جمجمه های انسانی

Background and purpose: Digital radiography has led to many improvements in radiology. Despite many advantages there are different ideas in determining anatomical landmarks which results in some errors in cephalometric analyses. The aim of this study was to determine the degree of identification differences of anatomical landmarks by conventional and digital lateral cephalometric techniques usi...

متن کامل

Comparison of cephalometric radiographs obtained from cone-beam computed tomography scans and conventional radiographs.

PURPOSE We evaluated whether measurements on conventional cephalometric radiographs are comparable to measurements on cone-beam computed tomography (CBCT)-constructed cephalometric radiographs taken from human skulls. MATERIALS AND METHODS The CBCT scans and conventional cephalometric radiographs were made using 40 dry skulls. With I-Cat Vision software (Imaging Sciences International, Inc, H...

متن کامل

cephalometric analysis obtained from computed tomography . Review of the literature

Introduction. The aim of this systematic review is to estimate accuracy and reproducibility of craniometric measurements and reliability of landmarks identified with computed tomography (CT) techniques in 3D cephalometric analysis. Methods. Computerized and manual searches were conducted up to 2011 for studies that addressed these objectives. The selection criteria were: (1) the use of human sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 1998