Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.

نویسندگان

  • Vera Bernet-Buettiker
  • Maria J Ugarte
  • Bernhard Frey
  • Maja Isabelle Hug
  • Oskar Baenziger
  • Markus Weiss
چکیده

OBJECTIVE Arterial oxygen saturation (Sao(2)) and arterial carbon dioxide partial pressure (Paco(2)) are 2 of the most important respiratory parameters in the treatment of critically ill neonates. Noninvasive monitoring of these parameters is desirable for continuous estimating of the respiratory status and reducing blood loss because of repeated blood gas analyses. Transcutaneous measurement of Pco(2) (Ptcco(2)) represents a simple and noninvasive technique for continuous monitoring of ventilation. However, sensor preparation, positioning, taping, and repeated changes of the sensor location make the handling difficult and complicate its use in the neonatal care unit. Recently, a new sensor for combined assessment of pulse oximetry oxygen saturation (Spo(2)) and Ptcco(2) has been introduced (TOSCA Monitor; Linde Medical Sensors, Basel, Switzerland). The monitor combines pulse oximetry and Ptcco(2) measurement in a single ear sensor, which works at 42 degrees C to enhance blood flow in capillaries below the sensor. METHODS In a prospective, open, nonrandomized study of 60 ill neonates, the new ear sensor for combined assessment of Spo(2) and Ptcco(2) at 42 degrees C was tested. The sensor was adapted to the ear of a neonate with a Varihesive layer (Conva Tec; Princeton, NJ). Data obtained from the ear sensor were compared with Spo(2 Finger/Heel), Sao(2), and Paco(2) obtained from arterial blood gas in 30 patients and with a capillary blood gas in an additional 30 patients using Bland Altman bias analysis. Data are presented as median (range). RESULTS The postconceptional age of the patients was 38.3 weeks (range: 28 5/7-40 5/7) in the arterial group and 37.9 weeks (range: 29 6/7-41 0/7) in the capillary group. Age of the newborns studied was 3.5 days (range: 1-28) in the arterial blood sample group (n = 30) and 6 days (range: 2-28) in the capillary blood sample group (n = 30). Patient weight was 3.02 kg (range: 1.5-4.5) in the arterial group and 2.76 kg (range: 1.0-3.71) in the other group. Three patients had weights of <1500 g. Twenty-one of 60 patients were conventionally ventilated, 4 patients received high-frequency oscillation, and 35 were not ventilated. Mean difference (bias) and precision (2 SD of the mean difference) between Ptcco(2 TOSCA) and Paco(2) were -0.44 kPa (-3.21 mm Hg) and 0.82 kPa (6.02 mm Hg) and between Ptcco(2 TOSCA) and Pcapco(2) were -0.09 kPa (-0.67 mm Hg) and 1.11 kPa (8.07 mm Hg), respectively. Spo(2) assessment by the TOSCA revealed slightly higher values compared with Sao(2) (bias: -0.48%), whereas Spo(2) (Finger/Heel) values were slightly lower than Sao(2) (bias: 0.52%). CONCLUSION The TOSCA monitor with the ear sensor adapted to ears of neonates allows reliable estimation of Sao(2) and Paco(2). A potential benefit is the reduction in motion artifacts because of less head movement in newborns and that only a single cable leads form the patient to the monitor. In addition, the sensor is not removed for chest radiograph or for nursing the infant on his or her parent's lap. Long-term studies in a large population with continuous measurements are required to confirm these preliminary findings and to elucidate the benefits in detection of respiratory deterioration and the potential side effects of this sensor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined pulse oximetry/cutaneous carbon dioxide tension monitoring during colonoscopies: pilot study with a smart ear clip.

BACKGROUND We compared the accuracy and practicability of a new combined ear sensor device measuring pulse oximetry and transcutaneous carbon dioxide tension. METHODS Validation studies were done by comparing the results of the combined sensor with arterial blood gas measurements. In an observational part, monitoring data were obtained from 25 patients undergoing colonoscopy, sedated with mid...

متن کامل

Monitoring carbon dioxide tension and arterial oxygen saturation by a single earlobe sensor in patients with critical illness or sleep apnea.

OBJECTIVES The purpose of the study was to evaluate a novel, combined sensor for transcutaneous monitoring of arterial oxygen saturation and carbon dioxide tension. DESIGN The new monitoring technique was compared to established reference methods. SETTING ICU and sleep laboratory of a university hospital. PATIENTS Eighteen critically ill adult patients with acute respiratory failure or he...

متن کامل

Evaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns

Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...

متن کامل

Reference values of capillary blood saturation in neonates and its difference from pulse oximetry.

INTRODUCTION Haemoglobin saturation is an obligatory oxygen parameter in the assessment of neonatal oxygenation. Although, pulse oximetry is currently one of the major methods in the determination of haemoglobin saturation, capillary blood saturation is still present in the diagnostic process. As well known, haemoglobin saturation value of capillary blood is insufficiently accurate, but not as ...

متن کامل

Current analytical approaches to measuring blood analytes.

In recent years, laboratory testing in the critical-care setting has increased, a trend due, in part, to the evolution of electrochemical sensors. Various innovations have extended sensor lifetimes, reduced sensor maintenance, and led to the development of single-use and unit-use disposable sensors. These sensor technologies allow the accurate and precise determination, either at or near the be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatrics

دوره 115 1  شماره 

صفحات  -

تاریخ انتشار 2005