Optimization of a high sensitivity MRI receive coil for parallel human brain imaging

نویسندگان

  • Jacco A. de Zwart
  • Patrick J. Ledden
  • Peter van Gelderen
  • P. Kellman
  • Yuxi Pang
  • Renxin Chu
  • Jeff H. Duyn
چکیده

Two eight-channel MRI receive-only coils were developed to provide whole-brain coverage at 1.5 T and 3.0 T field strength, respectively. Objectives were an image signal-to-noise ratio superior to standard designs throughout the human brain, as well as high parallel imaging performance. Electro-magnetic field simulations were used to determine array diameter and inter-element coil gap. Low mutual inductive coupling was achieved at 1.5 and 3.0 T using high-impedance pre-amplifiers. Coils show an average SNR improvement over commercial birdcage coils of 2.4 and 2.3 for the 1.5 T and 3.0 T design, respectively. The mean of the noise-amplification factor related to reconstruction of under-sampled data (gfactor) was 1.03 for 2-fold under-sampled data (rate-2) and 1.22 for rate-3 at 1.5 T. For data acquired with the 3.0 T coil array, these values were respectively 1.06 for rate-2 and 1.37 for rate-3.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

A 32-channel Receive Array Coil for Pediatric Brain Imaging at 3T

Introduction: Pediatric MRI currently requires general anesthesia to preclude motion artifacts. With highly accelerated image encoding in conjunction motion navigators it may be possible to significantly reduce or even eliminate anesthesia. For research studies of brain development where anesthesia is not possible, improved motion robustness can significantly improve the success rate. Highly pa...

متن کامل

A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction.

We evaluate a wavelet-based algorithm to estimate the coil sensitivity modulation from surface coils. This information is used to improve the image homogeneity of magnetic resonance imaging when a surface coil is used for reception, and to increase image encoding speed by reconstructing images from under-sampled (aliased) acquisitions using parallel magnetic resonance imaging (MRI) methods for ...

متن کامل

SENSE optimization of a transceive surface coil array for MRI at 4 T.

Parallel imaging (PI) techniques employ the use of multiple radiofrequency (RF) channels to transmit and/or receive the NMR signal. In the current study we use a finite difference time domain (FDTD) method to simulate the electromagnetic fields of a RF coil array operating in transmit-receive (transceive) mode and receive-only mode. Optimization of these configurations for PI is studied as well...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002