Results of use of the pyrolytic carbon tilting disc Bjork-Shiley aortic prosthesis.

نویسندگان

  • J Fernandez
  • D Morse
  • V Maranhao
  • A S Gooch
چکیده

Replacement of the aortic valve with a new BjorkShiley prosthesis was performed in 1 10 patients during the period from November, 1971 to July, 1973. The previously reported Delrin-disc Bjork-Shiley valve had a built-in valvular leak of up to 10 percent due to .003” clearance. The new pyrolite-disc prosthesis is machined to a clearance of .001”. Excellent clinical results have been achieved in 99 of the survivors (90 percent), with followup from 3 to 20 months. There was no systolic ejection gradient across the prosthesis ln 16 patients studied. There were three early and five

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CARDIOVASCULAR MEDICINE Twenty year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses

Objective: To compare survival and outcome in patients receiving a mechanical or bioprosthetic heart valve prosthesis. Design: Randomised prospective trial. Setting: Tertiary cardiac centre. Patients: Between 1975 and 1979, patients were randomised to receive either a Bjork-Shiley or a porcine prostheses. The mitral valve was replaced in 261 patients, the aortic in 211, and both valves in 61 pa...

متن کامل

Haemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study.

Slater, S. D., Saflam, I. A., Bain, W. H., Turner, M. A., and Lawrie, T. D. V. (1974). Thorax, 29, 624-632. Haemolysis with Bjork-Shiley and Starr-Edwards prosthetic heart valves: a comparative study. A comparison was made of the haemolytic complications in 85 patients with two different types of Starr-Edwards cloth-covered ball and cage prosthesis with those in 44 patients with the Bjork-Shile...

متن کامل

Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses.

BACKGROUND Patients undergoing heart-valve replacement may receive a mechanical prosthesis, necessitating lifelong anticoagulant treatment, or a porcine bioprosthesis, which involves no absolute need for anticoagulants. METHODS We carried out a randomized, prospective trial to compare the durability of the Bjork-Shiley mechanical prosthesis (spherical tilting-disk model) and the incidence of ...

متن کامل

Aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis. Clinical experiences in 50 cases.

Single aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis has been performed in 50 patients since April 1971. None of the total of six deaths (12.0%) was attributable to malfunction of the prosthesis or to embolic complications. Follow-up examination showed insignificant or moderate prosthetic regurgitation in two patients and moderate paravalvular leakage in one patie...

متن کامل

Disc embolisation after minor strut fracture in a Björk-Shiley mitral valve prosthesis.

We report the successful management of a patient who suffered embolisation of a Bjork-Shiley mitral prosthetic valve disc after fracture of the minor strut. Emergency surgical treatment was responsible for her survival. The disc was recovered through the abdominal aorta at a subsequent operation, performed once the condition of the patient had stabilised. This experience confirms previous repor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 65 6  شماره 

صفحات  -

تاریخ انتشار 1974