Heterodyne common-path grating interferometer with Littrow configuration.
نویسندگان
چکیده
This paper presents a heterodyne common-path grating interferometer with Littrow configuration (HCGIL). The HCGIL can effectively overcome environmental disturbance effect and the DC offset and the amplitude variation of the measurement signals. Experimental results match well with the HP5529A results for long-range measurements. Results also show that the estimated measurement resolution is 0.15 ± 0.027 nm. The stability of the HCGIL is -0.41 ± 0.23 nm. Therefore, the HCGIL has potential for subnanometer resolution and long-range applications.
منابع مشابه
Polarization Sagnac interferometer with a common-path local oscillator for heterodyne detection
We describe a free-space common-path polarization Sagnac interferometer. The polarization Sagnac interferometer is used in a symmetric fashion with detection on the dark fringe of the interference to avoid photodetector saturation when high-powered illumination is used. By modulating the carrier field that is reflected from the interferometer, we generate a local oscillator for heterodyne detec...
متن کاملA Common-Path Heterodyne Interferometer for Surface Profiling in Microelectronic Fabrication
Articles you may be interested in Improved common-path fast-scanning heterodyne interferometer system as potential dense-plasma diagnostics Rev. Power spectral densities: A multiple technique study of different Si wafer surfaces A prototype imaging second harmonic interferometer Rev. We describe the design of a common-path heterodyne laser interferometer for the surface profiling of micron-size...
متن کاملError Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer
A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...
متن کاملModeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm
Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...
متن کاملCharacterization of polarization sensitive, high efficiency dielectric gratings for formation flight interferometry
Reflective diffraction gratings enable novel optical configurations that simplify and improve laser interferometers. We have proposed an all-reflective grating interferometer that can be used in LISA type interferometers for space gravitational wave detection [1]. One configuration requires a highly polarization sensitive grating. We report on characterizations of a grating made atop high refle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 21 11 شماره
صفحات -
تاریخ انتشار 2013