Analytical recovery of folate degradation products formed in human serum and plasma at room temperature.

نویسندگان

  • Rita Hannisdal
  • Per Magne Ueland
  • Simone J P M Eussen
  • Asbjørn Svardal
  • Steinar Hustad
چکیده

Folate is not stable in serum and plasma. This may impair laboratory diagnostics and distort the outcome of epidemiological studies on folate and chronic diseases. The present study was designed to determine the kinetics of folate loss in human serum and plasma (collected into tubes containing EDTA, heparin, or citrate) at room temperature and the recovery of folate as 4-alpha-hydroxy-5-methyltetrahydrofolate (hmTHF) or p-aminobenzoylglutamate (pABG) equivalents. Different folate species and pABG were determined by liquid chromatography-tandem MS and microbiologically active folate was measured by a Lactobacillus rhamnosus assay. Concentrations of 5mTHF and microbiologically active folate had a parallel and rapid decrease in EDTA plasma to approximately 60% of the initial concentration after 24 h. In serum, heparin plasma, and citrate plasma, folate decreased more slowly to approximately 50% after 192 h. The loss of 5mTHF that occurred within 48 h was totally recovered as hmTHF. Folate measured as pABG equivalents decreased slowly to approximately 80% in 192 h and the decline was essentially matrix independent. In conclusion, the degradation of 5mTHF and microbiologically active folate in serum and plasma at room temperature can largely be corrected for by determining hmTHF or measuring folate as pABG equivalents. Moreover, results obtained using conventional folate assays may be biased by improper sample handling or if samples contained high concentrations of hmTHF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-Aqueous Electromigration Analysis of Some Degradation Products of Carvedilol

A capillary electrophoresis method was used for assay of some degradation products of carvedilol. The optimized parameters were as; running buffer 80 mM acetate dissolved in methanol/ethanol mixture (65:35 v/v), applied voltage of 19 kV, temperature is 20 ºC and the wavelength range of 200-350 nm. The results indicate that the proposed CE method could effectively separate carvedilol from its de...

متن کامل

Non-Aqueous Electromigration Analysis of Some Degradation Products of Carvedilol

A capillary electrophoresis method was used for assay of some degradation products of carvedilol. The optimized parameters were as; running buffer 80 mM acetate dissolved in methanol/ethanol mixture (65:35 v/v), applied voltage of 19 kV, temperature is 20 ºC and the wavelength range of 200-350 nm. The results indicate that the proposed CE method could effectively separate carvedilol from its de...

متن کامل

Interaction of Pyrene with Human Serum Albumin (HSA): A Ilv-Vis Spectroscopy Study

In this research the interaction of Pyrene (Cullm) as a polycyclic aromatic hydrocarbon with human serumalbumin (HSA) has been investigated. Variations of UV-Vis spectrum of Prene can help us to investigatethe changes that are ereated in protein structure. Pyrene in insoluble in water and soluble in acetic acid.mixture of acetic acid and water and in organic solvents such as methanol. UV-Vis sp...

متن کامل

اثر نان غنی شده با فولات بر وضعیت هوموسیستیین، فولات و ویتامین 12B افراد هیپرهوموسیستیینیمیک 70-60 ساله: مطالعه هوموسیستیین تهران

Background: Fortification of corn with folic acid has beneficial effects on hyperhomocysteinemia and heart disease. Folate fortification was contributed to an increase in average folate status and a reduction in serum homocysteine concentration. Methods: In this randomized clinical trial 17 men and women aged 61±5 years old with hyperhomocysteinemia with mean homocysteine concentration of 15/32...

متن کامل

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM

A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of nutrition

دوره 139 7  شماره 

صفحات  -

تاریخ انتشار 2009