Study of Optimal Operation for Huai'an Parallel Pumping Stations with Adjustable-Blade Units Based on Two Stages Decomposition-Dynamic Programming Aggregation Method

نویسندگان

  • Yi Gong
  • Jilin Cheng
  • Rentian Zhang
  • Lihua Zhang
چکیده

Two-stage decomposition-dynamic programming aggregation method has been first proposed and introduced to solve the mathematical model of daily optimal operation for parallel pumping stations with adjustable-blade units. Taking minimal daily electricity cost of single pump station as objective function, the water quantity pumped by each station as coordinated variable, by means of the type of the pump units this model is decomposed into several first-stage sub-model of daily optimal operation with adjustable-blade for single pump station. Then taking minimal daily electricity cost of single pump unit as objective function, the water quantity pumped by each unit as coordinated variable, the first-stage sub-model is decomposed into several second-stage sub-model of daily optimal operation with adjustable-blade for single pump unit which takes the blade angle as decision variable, the discrete values of water quantity pumped by each unit as state variable, and is solved by means of dynamic programming method. The constructed aggregation model takes daily water quantity pumped by each pump unit as decision variable, the discrete values of water quantity pumped by parallel station group as state variable, and is also solved by dynamic programming method. The aggregation process replaces the traditional method of constructing equations. This method has first solved the optimal operation issues for multi-units of parallel stations with various operation modes, time period division and daily average head of each station, and also provided theoretical support for the study on optimal operation of multi-stage pumping stations. Taking Huai'an No.1, No.2, and No.4 parallel pumping stations as a study case, a series of optimization results have been obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robust Energy Cost Optimization of Water Distribution System with Uncertain Demand

A methodology, based on the concept of Affinely Adjustable Robust Optimization, for optimizing daily operation of pumping stations is proposed, which takes into account the fact that a water distribution system in reality is unavoidably affected by uncertainties. For operation control, the main source of uncertainty is the uncertainty in the demand. Traditional methods for optimizing dynamical ...

متن کامل

Hierarchy Style Application in Line Extension with Responsive Loads Evaluating the Dynamic Nature of Solar Units

This paper presents a model for line extension scheduled to participate in responsive loads in the power system aiming the improvement of techno-economical parameters. The model is studied with the presence of photovoltaic generators that produce variable power depending on the geographical condition. The investment cost of the transmission expansion plan, demand response operation cost, genera...

متن کامل

presentation of a two stages method to determine the suitable benchmark and return to scale (case study: girls high school of one zone shiraz city)

In this paper, a two stages method to determine suitable benchmark and return scale of the decision making units set is presented. At first, all of the efficient reference set in no radial data envelopment analysis (DEA) based on linear programming is found. first, RAM model is introduced and units is investigated using this model, then, to run the given algorithm below steps is performed. At t...

متن کامل

The optimal energy carriers substitutes in thermal power plants:A fuzzy linear programming model

In this paper, a dynamic optimization approach for optimal choice of energy carriers in thermal power plants is proposed that analyzes the substitution of energy carriers in short-term planning of a power plant.The model is based on the linear programming method with the objective of minimizing costs under constraints of resource availability, energy balances, environmental regulations and elec...

متن کامل

A SAIWD-Based Approach for Simultaneous Reconfiguration and Optimal Siting and Sizing of Wind Turbines and DVR units in Distribution Systems

In this paper, a combination of simulated annealing (SA) and intelligent water drops (IWD) algorithm is used to solve the nonlinear/complex problem of simultaneous reconfiguration with optimal allocation (size and location) of wind turbine (WT) as a distributed generation (DG) and dynamic voltage restorer (DVR) as a distributed flexible AC transmission systems (DFACT) unit in a distribution sys...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010