Validation of distal limb mounted inertial measurement unit sensors for stride detection in Warmblood horses at walk and trot
نویسندگان
چکیده
BACKGROUND Inertial measurement unit (IMU) sensor-based techniques are becoming more popular in horses as a tool for objective locomotor assessment. OBJECTIVES To describe, evaluate and validate a method of stride detection and quantification at walk and trot using distal limb mounted IMU sensors. STUDY DESIGN Prospective validation study comparing IMU sensors and motion capture with force plate data. METHODS A total of seven Warmblood horses equipped with metacarpal/metatarsal IMU sensors and reflective markers for motion capture were hand walked and trotted over a force plate. Using four custom built algorithms hoof-on/hoof-off timing over the force plate were calculated for each trial from the IMU data. Accuracy of the computed parameters was calculated as the mean difference in milliseconds between the IMU or motion capture generated data and the data from the force plate, precision as the s.d. of these differences and percentage of error with accuracy of the calculated parameter as a percentage of the force plate stance duration. RESULTS Accuracy, precision and percentage of error of the best performing IMU algorithm for stance duration at walk were 28.5, 31.6 ms and 3.7% for the forelimbs and -5.5, 20.1 ms and -0.8% for the hindlimbs, respectively. At trot the best performing algorithm achieved accuracy, precision and percentage of error of -27.6/8.8 ms/-8.4% for the forelimbs and 6.3/33.5 ms/9.1% for the hindlimbs. MAIN LIMITATIONS The described algorithms have not been assessed on different surfaces. CONCLUSIONS Inertial measurement unit technology can be used to determine temporal kinematic stride variables at walk and trot justifying its use in gait and performance analysis. However, precision of the method may not be sufficient to detect all possible lameness-related changes. These data seem promising enough to warrant further research to evaluate whether this approach will be useful for appraising the majority of clinically relevant gait changes encountered in practice.
منابع مشابه
Evaluation of Palmar Digital Nerve Block and Distal Interphalangeal Joint Analgesia in Lame Horses Associated with Hoof Pain due to Sidebone Fracture
Objective- To determine if the pain of the third phalanx due to sidebone fracture in horses can be attenuated by analgesia of the distal interphlangeal joint and palmar digital nerve block. Design- Clinical study. Animals- Seven horses with unilateral forelimb lameness associated with hoof pain due to sidebone fracture. Procedures- Seven mix breed show jumping horses were selected from hor...
متن کاملStride-related rein tension patterns in walk and trot in the ridden horse
BACKGROUND The use of tack (equipment such as saddles and reins) and especially of bits because of rein tension resulting in pressure in the mouth is questioned because of welfare concerns. We hypothesised that rein tension patterns in walk and trot reflect general gait kinematics, but are also determined by individual horse and rider effects. Six professional riders rode three familiar horses ...
متن کاملAccuracy and Precision of Equine Gait Event Detection during Walking with Limb and Trunk Mounted Inertial Sensors
The increased variations of temporal gait events when pathology is present are good candidate features for objective diagnostic tests. We hypothesised that the gait events hoof-on/off and stance can be detected accurately and precisely using features from trunk and distal limb-mounted Inertial Measurement Units (IMUs). Four IMUs were mounted on the distal limb and five IMUs were attached to the...
متن کاملValidation of vertical ground reaction forces on individual limbs calculated from kinematics of horse locomotion.
The purpose of this study was to determine whether individual limb forces could be calculated accurately from kinematics of trotting and walking horses. We collected kinematic data and measured vertical ground reaction forces on the individual limbs of seven Warmblood dressage horses, trotting at 3.4 m s(-1) and walking at 1.6 m s(-1) on a treadmill. First, using a segmental model, we calculate...
متن کاملA Real-time Motion Tracking Wireless System for Upper Limb Exosuit Based on Inertial Measurement Units and Flex Sensors (TECHNICAL NOTE)
This paper puts forward a real-time angular tracking (motion capture) system for a low cost upper limb exosuit based on sensor fusion; which is integrated by an elastic sleeve-mitten, two inertial measurement units (IMU), two flex sensors and a wireless communication system. The device can accurately detect the angular position of the shoulder (flexion-extension, abduction-adduction and interna...
متن کامل