Enhanced Loadability of Existing Ehvac Line by Combined Ac-dc Transmission System
نویسندگان
چکیده
Now-a-days, demand for electric power has shown steady but geographically uneven growth.The wheeling of the available energy through existing long ac lines to load centers has a certain upper limit due to stability considerations. Thermal limit is the major limit to be considered while increasing loadability of existing EHV long transmission lines. Thus, these lines cannot be loaded to their thermal limit to keep sufficient margin against transient instability. This paper presents the concept of composite ac-dc power transmission. The conductors are allowed to carry usual ac along with dc superimposed on it. This will load the transmission lines close to its thermal limit thereby increasing the stability of the system. This paper presents the feasibility of converting a double circuit ac line into composite ac–dc power transmission line to get the advantages of parallel ac–dc transmission to improve stability and damping out oscillations. No alterations of conductors, insulator strings, and towers of the original line are needed. The proposed scheme is digitally simulated with the help of MATLAB software package. Simulation results clearly indicate the substantial increase in loadability of existing EHV AC lines by combined ac-dc transmission.
منابع مشابه
Power Upgrading of Transmission Line by Injecting DC Power in to AC Line with the help of ZIG-ZAG Transformer
We never loaded a long extra high voltage to their thermal limits in order to keep sufficient margin against transient instability. With this scheme proposed in this paper, it is possible to load these lines very near to their thermal limits. Here we inject dc power in to dc transmission line to carry usual ac along with dc superimposed on it. The added power flow does not cause any transient i...
متن کاملOptimal Agc of Deregulated Interconnected Power System with Parallel Ac / Dc Link
This paper presents optimal AGC regulator design of deregulated power system based on the full state feedback control strategy. The two-area interconnected power system of identical nature consisting of non-reheat turbine is considered for the investigations. The areainterconnection of the power system via parallel EHVAC/HVDC transmission link is considered. The proposed controller is applied t...
متن کاملComparison of SVC and STATCOM in Static Voltage Stability Margin Enhancement
One of the major causes of voltage instability is the reactive power limit of the system. Improving the system's reactive power handling capacity via Flexible AC transmission System (FACTS) devices is a remedy for prevention of voltage instability and hence voltage collapse. In this paper, the effects of SVC and STATCOM in Static Voltage Stability Margin Enhancement will be studied. AC and DC r...
متن کاملOptimal Placement and Sizing of FACTS Devices for Loadability Enhancement in Deregulated Power Systems
This paper presents the use of Flexible AC Transmission Systems (FACTS) for improving loadability of the system in deregulated electric power system.The optimallocation and parameter settingsof two types of FACTS devices have been investigated in this study. The Static Synchronous Series Compensator (SSSC) and Thyristor Controlled Series Compensation (TCSC) as two FACTS devices are considered i...
متن کاملA Novel Method to Increase the Power Capacity of Transmission Lines Using Transformerless Static Synchronous Series Compensator
In this paper a transformerless Static Synchronous Series Compensator (SSSC) to increase the power capacity of a 230 kV transmission line is proposed. In order to eliminate the transformer, a 15-level cascade H Bridge (CHB) inverter is employed within the proposed compensator structure to inject reactive power to the transmission line. The theory of instantaneous p-q power using in the compensa...
متن کامل