The self-adjusting file (SAF). Part 2: mechanical analysis.
نویسندگان
چکیده
INTRODUCTION The study was designed to explore the mechanical properties of the self-adjusting file (SAF) and its application in the root canal using continuous irrigation. METHODS The compressibility of the SAF file and the resulting peripheral force were measured using specially designed systems. The abrasivity of the file was tested on dentin blocks representing a flat root canal. The durability of the SAF file was tested using a functional fatigue-to-failure assay. Degradation of the file was evaluated by using files that were previously used for 10, 20, and 30 minutes and comparing their efficacy with that of new, unused files. The potential of extruding irrigant beyond the apex was explored in roots with an open apical foramen. RESULTS The SAF file was elastically compressible from a diameter of 1.5 mm to dimensions similar to those of a #20 stainless steel K-file. This compression resulted in an evenly applied force to the root canal walls. The in-and-out vibration of the file and the peripheral force, combined with its abrasivity, allow for hard-tissue removal. Under the conditions of the experiment, no mechanical failure was observed with up to 29 minutes of operation in the root canal. The file loses its efficacy after prolonged use, with a 40% reduction after 30 minutes of operation. The operation of the file with continuous irrigation did not push the irrigant beyond an open apical foramen. CONCLUSIONS The SAF file is an elastically compressible file that effectively removes dentin and can mechanically endure use under its recommended mode of operation with a minimal loss of efficacy.
منابع مشابه
The self-adjusting file (SAF). Part 1: respecting the root canal anatomy--a new concept of endodontic files and its implementation.
AIM To introduce a new concept, the self-adjusting file (SAF), and discuss its unique features compared with current rotary nickel-titanium file systems. THE NEW CONCEPT The SAF file is hollow and designed as a thin cylindrical nickel-titanium lattice that adapts to the cross-section of the root canal. A single file is used throughout the procedure. It is inserted into a path initially prepar...
متن کاملEfficacy of Different Irrigation Systems Used to Remove Calcium Hydroxide from the Root Canal
Introduction: The present study aimed to compare the cleaning efficacy of passive ultrasonic irrigation (PUI), self-adjusting file (SAF), EndoVac, and conventional syringe irrigation (CSI) techniques on Ca(OH)2 removal from the root canal. Methods: This study was conducted on the mesial roots of 36 human mandibular molar teeth. After 1 month, the Ca(...
متن کاملFlat-oval root canal preparation with self-adjusting file instrument: a micro-computed tomography study.
INTRODUCTION The aim of this study was to evaluate the root canal preparation in flat-oval canals treated with either rotary or self-adjusting file (SAF) by using micro-tomography analysis. METHODS Forty mandibular incisors were scanned before and after root canal instrumentation with rotary instruments (n = 20) or SAF (n = 20). Changes in canal volume, surface area, and cross-sectional geome...
متن کاملPreservation of root canal anatomy using self-adjusting file instrumentation with glide path prepared by 20/0.02 hand files versus 20/0.04 rotary files
OBJECTIVES To compare the relative axis modification and canal concentricity after glide path preparation with 20/0.02 hand K-file (NITIFLEX®) and 20/0.04 rotary file (HyFlex™ CM) with subsequent instrumentation with 1.5 mm self-adjusting file (SAF). MATERIALS AND METHODS One hundred and twenty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer, Ballaigues, Switzerland) were acquire...
متن کاملEfficacy of Two Irrigants Used with Self-Adjusting File System on Smear Layer: A Scanning Electron Microscopy Study
Mechanical instrumentation of root canals produces a smear layer that adversely affects the root canal seal. The aim of this study was to evaluate efficacy of MTAD and citric acid solutions used with self-adjusting file (SAF) system on smear layer. Twenty-three single-rooted human teeth were used for the study. Canals were instrumented manually up to a number 20 K file size. SAF was used to pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endodontics
دوره 36 4 شماره
صفحات -
تاریخ انتشار 2010