The use of trans-applicator intracavitary ultrasonography in brachytherapy for cervical cancer: phantom study of a novel approach to 3D image-guided brachytherapy
نویسندگان
چکیده
PURPOSE To assess the feasibility of applying trans-applicator intracavitary ultrasonography to image-guided brachytherapy for cervical cancer. MATERIAL AND METHODS For this experiment, a phantom was created and included a polyethylene tube, intended to simulate a tandem applicator, which was inserted into chicken meat and embedded in agar, along with magnetic resonance imaging (MRI)-compatible ovoid applicators. Three-dimensional images of the phantom were obtained using computed tomography (CT), MRI (T2-weighted), and intracavitary ultrasonography sectional images acquired at 1 mm slice intervals. Intracavitary ultrasonography images were acquired from within the simulated tandem applicator using a radial transducer. Magnetic resonance imaging and intracavitary ultrasonography images were manually registered onto CT images. The chicken meat was contoured as the target volume independently on the CT, MRI, and intracavitary ultrasonography images, and the Dice similarity coefficient was used to compare the target volumes. The dose distributions of a sample brachytherapy plan were also evaluated. RESULTS Computed tomography, MRI, and intracavitary ultrasonography all visualized the three-dimensional phantom volumes. Intracavitary ultrasonography images depicted the meat with high echoic signals and a border clearly distinguishable from the surrounding agar. The Dice similarity coefficient values for the target volumes on CT vs. MRI, CT vs. intracavitary ultrasonography, and MRI vs. intracavitary ultrasonography were 0.966, 0.965, and 0.971, respectively, indicating similar contouring with the three modalities. Among the modalities, the differences in D50, D90, D98, and D100 values were 1.8%, 2.9%, 3.7%, and 2.9%, respectively. CONCLUSIONS Three-dimensional reconstructed trans-applicator intracavitary ultrasonographic images clearly depicted meat tissue within the phantom, and could thus be used for brachytherapy planning. This study proves the concept of trans-applicator intracavitary ultrasonography for intracavitary brachytherapy. Further research such as development of intracavitary ultrasonography system, 3D reconstruction method, ultrasonography-compatible applicators, and ultrasonography-based target concept is warranted to assess the potential clinical application.
منابع مشابه
Routine use of ultrasound guided tandem placement in intracavitary brachytherapy for the treatment of cervical cancer – a South Indian institutional experience
PURPOSE Intracavitary brachytherapy necessitates the insertion of a tandem applicator through the cervical os into the uterine cavity. Blind insertion of the tandem may result in suboptimal tandem placement. This decreases the control of the tumor locally and may result in uterine perforation. Although routine real time ultrasound guided tandem placement has shown better results, it is seldom p...
متن کاملDeveloping a Verification and Training Phantom for Gynecological Brachytherapy System
Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...
متن کاملAccuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...
متن کاملDirection Modulated Brachytherapy for Treatment of Cervical Cancer. II: Comparative Planning Study With Intracavitary and Intracavitary-Interstitial Techniques.
PURPOSE To perform a comprehensive comparative planning study evaluating the utility of the proposed direction modulated brachytherapy (DMBT) tandem applicator against standard applicators, in the setting of image guided adaptive brachytherapy of cervical cancer. METHODS AND MATERIALS A detailed conceptual article was published in 2014. The proposed DMBT tandem applicator has 6 peripheral gro...
متن کاملA comparison of dose distribution from Manchester-style and Fletcher-style intracavitary brachytherapy applicator systems in cervical cancer
PURPOSE During intracavitary brachytherapy (ICBT) for cervical cancer, the choice of applicator system remains rather arbitrary. However, as the applicator geometry may play an important role in dose distribution, thereby improving the therapeutic ratio, this study was conducted to compare the Manchester-style and Fletcher-style applicator systems. MATERIAL AND METHODS After completion of EBR...
متن کامل