False-positive rate of a "fourth-generation" HIV antigen/antibody combination assay in an area of low HIV prevalence.

نویسندگان

  • Sinyoung Kim
  • Jong-Han Lee
  • Jun Yong Choi
  • June Myung Kim
  • Hyon-Suk Kim
چکیده

We retrospectively analyzed the performance of the Architect HIV antigen/antibody (Ag/Ab) combination assay in a tertiary health care center with a situation of low HIV prevalence. The specificity and positive predictive value (PPV) were 99.78% and 31.21%, respectively. However, the specificity and PPV could increase to 99.99% and 89.70% using an arbitrary cutoff value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of the HIV Seroconversion Window Period and False Positive Rate by Using ADVIA Centaur HIV Antigen/Antibody Combo Assay

BACKGROUND Early diagnosis of HIV infection reduces morbidity and mortality. Fourth-generation HIV detection assays are more sensitive because they can detect p24 antigen as well as anti-HIV antibodies. In this study, we evaluated the performance of a new fourth-generation ADVIA Centaur HIV antigen/antibody combo (CHIV) assay (Siemens Healthcare Diagnostics Inc., USA) for early detection of HIV...

متن کامل

Programmatic Evaluation of a Combined Antigen and Antibody Test for Rapid HIV Diagnosis in a Community and Sexual Health Clinic Screening Programme

BACKGROUND A substantial proportion of HIV-infected individuals in the UK are unaware of their status and late presentations continue, especially in low prevalence areas. Fourth generation antigen/antibody rapid test kits could facilitate earlier diagnosis of HIV in non-clinical settings but lack data on performance under programmatic conditions. METHODS AND FINDINGS We evaluated the performa...

متن کامل

Multicenter evaluation of a new automated fourth-generation human immunodeficiency virus screening assay with a sensitive antigen detection module and high specificity.

Fourth-generation assays for the simultaneous detection of human immunodeficiency virus (HIV) antigen and antibody that were available on the international market until now have antigen detection modules with relatively poor sensitivity and produce a higher rate of false-positive results than third-generation enzyme immunoassays (EIAs). The new Cobas Core HIV Combi EIA with an improved sensitiv...

متن کامل

Human Immunodeficiency Virus Diagnostic Testing: 30 Years of Evolution.

A concern during the early AIDS epidemic was the lack of a test to identify individuals who carried the virus. The first HIV antibody test, developed in 1985, was designed to screen blood products, not to diagnose AIDS. The first-generation assays detected IgG antibody and became positive 6 to 12 weeks postinfection. False-positive results occurred; thus, a two-test algorithm was developed usin...

متن کامل

Sero-prevalence of Herpes Simplex and Epstein Barr Viruses in HIV positive patients in Tehran

Abstract Background and Aims: The burden of HIV infection and disease continues to be a major global public health concern all over the world. This study was conducted to measure IgG antibody against EBV viral capsid antigen (EBV-VCA IgG), Herpes Simplex Type1, and 2 to determine the seroprevalence of this infection in HIV-positive population. Materials and Methods: A Cross-sectional st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and vaccine immunology : CVI

دوره 17 10  شماره 

صفحات  -

تاریخ انتشار 2010