Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse

نویسندگان

  • Min-Ho Jun
  • Young-Min Kim
  • Jang-Han Bae
  • Chang Jin Jung
  • Jung-Hee Cho
  • Young Ju Jeon
چکیده

The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB) as one of the sensor combination methods. The three-layered housing structure that included independent pressure sensor units using the FDB method not only enabled elimination of the crosstalk among channels, but also allowed various array patterns to be created for effective pulse measurement. The sensors were arranged in a circular-type arrangement such that they could estimate the direction of the radial artery and precisely measure the pulse wave. The performance of the fabricated sensor array was validated by evaluating the sensor sensitivity per channel, and the possibility of estimating the blood vessel direction was demonstrated through a radial artery pulse simulator. We expect the proposed sensor to allow accurate extraction of the pulse indices for pulse diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Caution using brachial systolic pressure to calibrate radial tonometric pressure waveforms: lessons from invasive study.

Caution Using Brachial Systolic Pressure to Calibrate Radial Tonometric Pressure Waveforms: Lessons From Invasive Study To the Editor: We were very interested to read the recent article by Segers et al1 that prompted the correspondence from O’Rourke and Takazawa,2 who were concerned about the reliability of brachial artery tonometry and the lack of relevant invasive data, as well as the subsequ...

متن کامل

Development of a Radial Pulse Tonometric (RPT) Sensor with a Temperature Compensation Mechanism

Several RPT sensors have been developed to acquire objective and quantitative pulse waves. These sensors offer improved performance with respect to pressure calibration, size and sensor deployment, but not temperature. Since most pressure sensors are sensitive to temperature, various temperature compensation techniques have been developed, but these techniques are largely inapplicable to RPT se...

متن کامل

Measurement of Spatial Pulse Wave Velocity by Using a Clip-Type Pulsimeter Equipped with a Hall Sensor and Photoplethysmography

A prototype of a clip-type pulsimeter equipped with a magnetic field-sensing semiconductor Hall sensor was developed. It has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. To measure spatial pulse wave velocity (SPWV), the signal from the radial artery pulsimeter and that ...

متن کامل

Development of a Disposable Electrochemical Sensor based on Nanocomposite/Ionic Liquid Assisted Hollow Fiber-Graphite Electrode for Measurement of Lorazepam Using Central Composite Design

In this study a new method of preconcentration, separation and efficient measuring of so-called hollow fiber solid / liquid phase microextraction has been introduced for the determination of trace amounts of lorazepam (LRZ) in water samples, urine and hair using differential pulse voltammetry. To this end, a hybrid adsorbent material was used that involved ionic liquid assisted magnetic multi-w...

متن کامل

Performance Improvements of a Centrifugal Pump with Different Impellers using Polymer Additive

In this study, the performance of a centrifugal pump is investigated by adding polyacrylamide (PAM) polymer over the working fluid which is tap water in this case. PAM is a long chain polymer that leads to reduce the wall shear stress and drag in a turbulent fluid. Three different blade profiles including radial, straight backward and circular backward have been examined. For this purpose, a ce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016