Assessment of regional myocardial blood flow and regional fractional oxygen extraction in dogs, using 15O-water and 15O-hemoglobin.

نویسندگان

  • J A Parker
  • G A Beller
  • B Hoop
  • B L Holman
  • T W Smith
چکیده

A new approach to the assessment of regional myocardial blood flow and fractional oxygen extraction has been developed using 15O-water (H2-15O) and 15O-hemoglobin (15O-Hb). Bolus doses (1 mCi) of H2-15O and 15O-Hb were injected 10 minutes apart into the left main coronary artery of 12 normal dogs. Sequential images of regional myocardial tracer clearance were obtained over 5 minutes with a positron camera. Myocardial blood flow calculated from the monoexponential washout of H2-15O after background correction was 78 +/- 6 (SE) ml/100 g per min. Functional images of regional blood flow in which the image of peak activity was divided by the integrated image of H2-15O washout were derived by computer processing. These images demonstrated homogeneous blood flow in the normal myocardium. Fractional myocardial O2 extraction was determined from an image of initial distribution of O2 used (obtained by extrapolating back to time zero the series of images obtained after 15O-Hb administration), divided by initial distribution of O2 delivered (obtained by back extrapolating H2-15O washout). These functional images showed uniform distribution of fractional O2 extraction in the normal myocardium. Thus, these studies show that regional myocardial blood flow and regional oxygen extraction can be measured simultaneously by sequential imaging after serial intracoronary injections of H2-15O and 15O-Hb.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct comparison of [13N]ammonia and [15O]water estimates of perfusion with quantification of regional myocardial blood flow by microspheres.

BACKGROUND Both [13N]ammonia and [15O]water have been used to quantify myocardial blood flow with positron emission tomography using appropriate tracer kinetic models. A direct comparison of the two tracers with radioactive microspheres has not been performed in the same experimental preparation. METHODS AND RESULTS The two tracers have been tested for myocardial blood flow quantification in ...

متن کامل

Regional cerebral blood flow measurement with intravenous [15O]water bolus and [18F]fluoromethane inhalation.

In 20 patients with ischemic cerebrovascular disease, classic migraine, or angiomas, we compared paired dynamic positron emission tomographic measurements of regional cerebral blood flow using both [15O]water and [18F]fluoromethane as tracers. Cerebral blood flow was also determined according to the autoradiographic technique with a bolus injection of [15O]water. There were reasonable overall c...

متن کامل

Parametric imaging of myocardial blood flow with 15O-water and PET using the basis function method.

UNLABELLED Regional myocardial blood flow (MBF) can be measured with 15O-water and PET using the 1-tissue-compartment model with perfusable tissue fraction, which provides an MBF value that is free from the partial-volume effect. Studies with 15O-water have several advantages, such as the ability to repeat a scan. However, because of the short scanning time and the small distribution volume of ...

متن کامل

Oxygen-15-water PET assessment of muscular blood flow in peripheral vascular disease.

UNLABELLED To assess quantitatively regional nutritive muscular blood flow in patients with peripheral vascular disease (PVD), we evaluated the utility of PET with 15O-water. METHODS Eight healthy volunteers and 16 patients with angiographically proven PVD were studied. Regional blood flow of the calf was measured with 15O-water PET during rest, after intra-arterial infusion of prostaglandin ...

متن کامل

Tumor blood flow measured by PET dynamic imaging of first-pass 18F-FDG uptake: a comparison with 15O-labeled water-measured blood flow.

UNLABELLED PET molecular imaging of 15O-labeled water is the gold standard for measuring blood flow in humans. However, this requires an on-site cyclotron to produce the short-lived 15O tracer, which is cost-prohibitive for most clinical PET centers. The purpose of this study was to determine if the early uptake of 18F-FDG could be used to measure regional blood flow in tumors in the absence of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 42 4  شماره 

صفحات  -

تاریخ انتشار 1978