Radiology stewardship and quality improvement: the process and costs of implementing a CT radiation dose optimization committee in a medium-sized community hospital system.
نویسندگان
چکیده
PURPOSE The aims of this study were to measure the effectiveness of a multidisciplinary CT dose optimization committee and estimate its costs and to describe a radiation stewardship quality improvement initiative in one CT department at a medium-sized community hospital system that used a participatory design committee methodology. METHODS A CT dose optimization committee was conceived, funded, and formed, consisting of the following stakeholders: radiologists, technologists, consultant medical physicists, and an administrator. Volume CT dose index (CTDIvol) and repeat rate were monitored for 1 month, for one scan type, during which iterative protocol adjustments were made through committee interaction. Effects on repeat rate and CTDIvol were quantified and benchmarked against national diagnostic reference levels after retrospective medical record review of 100 consecutive patients before and after the intervention. Labor hours were reported and wage resources estimated. RESULTS Over 3 months, the committee met in person twice and exchanged 128 e-mails in establishing a process for protocol improvement and measurement of success. Repeat rate was reduced from 13% (13 of 100) to 0% (0 of 100). Scans meeting the ACR reference level for CTDIvol (75 mGy) improved by 34% (38 of 100 before, 51 of 100 after; Fisher's exact 2-tailed P = .09), and those meeting ACR pass/fail criterion (80 mGy) improved by 29% (58 of 100 before, 75 of 100 after; Fisher's exact 2-tailed P = .01). Committee evolution and work, and protocol development and implementation, required 57 person-hours, at an estimated labor cost of $12,488. CONCLUSIONS An efficient process was established as a proof of concept for the use of a multidisciplinary committee to reduce patient radiation dose, repeat rate, and variability in image quality. The committee and process ultimately improved the quality of patient care, fostered a culture of safety and ongoing quality improvement, and calculated costs for such an endeavor.
منابع مشابه
Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملThyroid dose and dose reduction method from CT scan of head and neck
Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...
متن کاملImage Optimization and reduction of radiation dose in CT of the paranasal sinuses
Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...
متن کاملOptimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)
Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...
متن کاملEstimation of diagnostic reference levels for children computed tomography: A study in Tehran, Iran
Background: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the national computed tomo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Radiology : JACR
دوره 10 6 شماره
صفحات -
تاریخ انتشار 2013