Antioxidant potential of i.v. fluids.

نویسنده

  • N Stratford
چکیده

In acute clinical settings where there may be a role for antioxidant therapy, patients receive large amounts of i.v. fluids which may have antioxidant activity. To investigate such effects the antioxidant capacity of nine i.v. fluids was measured (Gelofusine, Haemaccel, 20% mannitol, 4.5% human albumin solution, fresh frozen plasma, aprotinin, N-acetylcysteine and two hydroxyethyl starch solutions). Results are expressed as mean mmol litre-1 Trolox equivalents. Mannitol 20% and the hydroxyethyl starch solutions had no antioxidant activity. Protein-containing solutions (gelatins, albumin and aprotinin) had antioxidant activity 50-66% that of plasma: Gelofusine 0.85 mmol litre-1; Haemaccel 0.78 mmol litre-1; 4.5% albumin 0.95 mmol litre-1; aprotinin 0.80 mmol litre-1; fresh frozen plasma 1.45 mmol litre-1. However, none was nearly as potent an antioxidant as the clinical preparation of N-acetylcysteine, with an antioxidant activity of 502 mmol litre-1. Studies of antioxidant therapy may need to take account of the antioxidant effect of i.v. fluids.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prophylactic and Therapeutic Effects of Oleuropein on Reperfusion-Induced Arrhythmia in Anesthetized Rat

Background: This study was conducted to reveal that whether i.v. injection of oleuropein, the most potent polyphenolic antioxidant in olive leaf, has any effect on the magnitude of reperfusion arrhythmia in anesthetized rats or not. Methods: Eighty male Wistar rats were divided into 8 groups of 10 each: groups 1 and 5 were assigned as the prophylactic and treatment control groups, groups 2 and ...

متن کامل

Clinical effectiveness and cost-effectiveness of prehospital intravenous fluids in trauma patients.

OBJECTIVES To systematically review the evidence on the effectiveness (in terms of mortality and morbidity) of prehospital intravenous (i.v.) fluid replacement, compared with no i.v. fluid replacement or delayed fluid replacement, in trauma patients with no head injury who have haemorrhage-induced hypotension due to trauma. DATA SOURCES Electronic databases, relevant websites, handsearching, ...

متن کامل

Errors of intravenous fluid infusion rates in medical inpatients.

Prescriptions for intravenous (i.v.) fluids in hospitals may not be closely adhered to. This study prospectively examined whether prescribed i.v. fluids are administered at the correct rate. During a four-week period, the i.v. infusion rates in patients requiring continuous i.v. fluids and cared for by a single medical team in a district hospital were studied. The periods over which i.v. crysta...

متن کامل

A Review of Laboratory Methods for Measuring Oxidative Stress

Introduction: Antioxidant defense system, including enzymatic and non-enzymatic antioxidants, protects cells from oxidative damage by neutralizing oxidant compounds. Increasing the production of oxidant species and decrease activity of antioxidant system causes oxidative stress. The role of oxidative stress in the pathogenesis of human diseases and strengthening of human antioxidant defense sys...

متن کامل

Time-periodic Electroosmotic Flow of Non-newtonian Fluids in Microchannels

The alternating current electroosmotic flow of a non-Newtonian power-law fluid is studied in a circular microchannel. A numerical method is employed to solve the non-linear Poisson-Boltzmann and the momentum equations. The main parameters which affect the flow field are the flow behavior index, the dimensionless zeta potential and the dimensionless frequency. At very low dimensionless frequenci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 78 6  شماره 

صفحات  -

تاریخ انتشار 1997