Evaluation of a 4D Cone-Beam CT Reconstruction Approach Using an Anthropomorphic Phantom

نویسندگان

  • Ziv Yaniv
  • Jan M. Boese
  • Marily Sarmiento
  • Kevin Cleary
چکیده

We have previously developed image-guided navigation systems for thoracic abdominal interventions utilizing a three dimensional (3D) Cone-Beam CT (CBCT) image acquired at breath-hold. These systems required the physician to perform the intervention in a gated manner, with actions performed at the same respiratory phase in which the CBCT image was acquired. This approach is not always applicable, as many patients find it hard to comply with the breath-hold requirement. In addition the physician’s actions are limited to a specific respiratory phase. To mitigate these deficiencies we have developed and implemented a retrospectively gated acquisition protocol using a clinical C-arm based system. The resulting 4D (3D+time) image is then used as input for the navigation system. We evaluate our reconstruction approach using a computer controlled anthropomorphic respiring phantom. The phantom is respired using respiratory rates of 12, 15 and 20 breaths per minute, and three amplitudes corresponding to shallow, normal, and deep breathing patterns. We show that the gated images have a better contrast to noise ratio and sharper edges than the images reconstructed without gating. Thus we are able to acquire an intra-operative data set that potentially provides better navigation accuracy, using 3D images at arbitrary points in the respiratory cycle without requiring the patient to hold their breath during image acquisition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...

متن کامل

Evaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators

Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...

متن کامل

Low-Dose and Scatter-Free Cone-Beam CT Imaging Using a Stationary Beam Blocker in a Single Scan: Phantom Studies

Excessive imaging dose from repeated scans and poor image quality mainly due to scatter contamination are the two bottlenecks of cone-beam CT (CBCT) imaging. Compressed sensing (CS) reconstruction algorithms show promises in recovering faithful signals from low-dose projection data but do not serve well the needs of accurate CBCT imaging if effective scatter correction is not in place. Scatter ...

متن کامل

Filtered-backprojection reconstruction for a cone-beam computed tomography scanner with independent source and detector rotations.

PURPOSE A new cone-beam CT scanner for image-guided radiotherapy (IGRT) can independently rotate the source and the detector along circular trajectories. Existing reconstruction algorithms are not suitable for this scanning geometry. The authors propose and evaluate a three-dimensional (3D) filtered-backprojection reconstruction for this situation. METHODS The source and the detector trajecto...

متن کامل

Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners

Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010