Sequential injection chromatography with a miniaturized multi-channel fiber optic detector for separation and quantification of propranolol and hydrochlorothiazide
نویسندگان
چکیده
BACKGROUND Sequential injection chromatography (SIC) is a new alternative separation technology. It has some advantages over high performance liquid chromatography (HPLC) regarding simplicity, inexpensiveness, portability, ease of use, maintenance requirement and operation time. In contrast, SIC has had suffered from some limitations. RESULTS The current work involves four achievements. (a) One of the limitations of SIC has been overcome. A higher pressure resistant selection valve with additional ports was installed in an SIC system. This development allows propelling solution without showing solution leakage. (b) A new inexpensive rapid and green method for the separation and quantification of propranolol (PRP) and hydrochlorothiazide (HTZ) in their formulations was optimized and validated. (c) A miniaturized multi-channel fiber optic detector was coupled with the newly developed SIC system to detect PRP and HTZ at 270 and 290 nm, respectively. This issue enhanced the sensitivity rather than using a single-channel detector. (d) A comparative study on the efficiency of the SIC method with that of previous HPLC methods was conducted. CONCLUSIONS Besides the benefits of the instrumentation of SIC, the proposed method is rapider and more reagent-saving than previous HPLC methods. The total volume of consumed reagents and sample was 4.04 mL. The sample frequency was 22 samples/h. Other such analytical characters of the SIC method as resolution, peak symmetry, numbers of theoretical plates, linearity range, accuracy, precision and limits of detection and quantification recorded comparable results.
منابع مشابه
Rapid Separation of Elemental Species by Fast Multicapillary Gas Chromatography with Multichannel Optical Spectrometry Detection following Headspace Solid Phase Microextraction
A method for conducting fast and efficient gas chromatography based on short multicapillaries in straight alignment combined with atomic emission detection was developed for field analysis. The strategy enables for speciation analysis of organometallic compounds. The analytes are simultaneously ethylated and preconcentrated on a solid phase microextraction (SPME) fiber placed in the headspace o...
متن کاملQuantification of identical and unique segments in ethylene-propylene copolymers using two dimensional liquid chromatography with infra-red detection
Hyphenating High Temperature High Performance Liquid Chromatography (HT-HPLC) with High Temperature Size Exclusion Chromatography (HT-SEC) (High Temperature Two Dimensional Liquid Chromatography (HT-HPLC x HT-SEC or HT 2D-LC)) leads to an isocratic elution in the second dimension, which in turn enables to use IR detector (quantitative detection) for monitoring the eluting polymers. Experimental...
متن کاملA fiber optic sensor for measuring glucose in aqueous solutions
In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...
متن کاملDevelopment of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol
A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...
متن کاملEvaluate The Behavior of PIN infrared detector via COMSOL software
Infrared detectors can be used for a variety of applications such as: using in fiber-optic communications. Conventional technology for IR detectors is using p-i-n structure based on GaAs compound. This paper reports on the design and modeling of an IR detector using a p-i-n GaAs structure. Comsol software is used to simulate the model and the detector is discussed for terminal current, dopant p...
متن کامل