Comparing neural networks and linear discriminant functions for glaucoma detection using confocal scanning laser ophthalmoscopy of the optic disc.

نویسندگان

  • Christopher Bowd
  • Kwokleung Chan
  • Linda M Zangwill
  • Michael H Goldbaum
  • Te-Won Lee
  • Terrence J Sejnowski
  • Robert N Weinreb
چکیده

PURPOSE To determine whether neural network techniques can improve differentiation between glaucomatous and nonglaucomatous eyes, using the optic disc topography parameters of the Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany). METHODS With the HRT, one eye was imaged from each of 108 patients with glaucoma (defined as having repeatable visual field defects with standard automated perimetry) and 189 subjects without glaucoma (no visual field defects with healthy-appearing optic disc and retinal nerve fiber layer on clinical examination) and the optic nerve topography was defined by 17 global and 66 regional HRT parameters. With all the HRT parameters used as input, receiver operating characteristic (ROC) curves were generated for the classification of eyes, by three neural network techniques: linear and Gaussian support vector machines (SVM linear and SVM Gaussian, respectively) and a multilayer perceptron (MLP), as well as four previously proposed linear discriminant functions (LDFs) and one LDF developed on the current data with all HRT parameters used as input. RESULTS The areas under the ROC curves for SVM linear and SVM Gaussian were 0.938 and 0.945, respectively; for MLP, 0.941; for the current LDF, 0.906; and for the best previously proposed LDF, 0.890. With the use of forward selection and backward elimination optimization techniques, the areas under the ROC curves for SVM Gaussian and the current LDF were increased to approximately 0.96. CONCLUSIONS Trained neural networks, with global and regional HRT parameters used as input, improve on previously proposed HRT parameter-based LDFs for discriminating between glaucomatous and nonglaucomatous eyes. The performance of both neural networks and LDFs can be improved with optimization of the features in the input. Neural network analyses show promise for increasing diagnostic accuracy of tests for glaucoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glaucoma-Induced Optic Disc Morphometric Changes and Glaucoma Diagnostic Ability of Heidelberg Retina Tomograph II in Highly Myopic Eyes

PURPOSE This study was performed to first investigate the morphological differences in the optic nerve head between highly myopic non-glaucomatous controls and highly myopic glaucomatous eyes in comparison with the differences between emmetropic non-glaucomatous controls and emmetropic glaucomatous eyes using confocal scanning laser ophthalmoscopy. Further, the ability of the apparatus in glauc...

متن کامل

Discriminant analysis models for early detection of glaucomatous optic disc changes.

AIM To evaluate and compare four different mathematical formulas for the early detection of morphometric optic nerve head changes in chronic open angle glaucoma. METHODS The optic nerve heads of 161 patients with perimetrically defined glaucomatous optic nerve damage and of 194 normal subjects were examined by confocal laser scanning tomography. Using four formulas of linear discriminant anal...

متن کامل

Diagnosis of glaucoma and detection of progression in the presence of concomitant diseases

Core Concepts • An examination of the neuroretinal rim and surrounding retinal nerve fiber layer is necessary to detect glaucomatous optic neuropathy. • Glaucoma often affects the superior and inferior poles of the disc. • Presence of disc hemorrhage and/ or retinal nerve fibre layer defects is very suggestive of glaucoma. • Most automated perimeters report age-adjusted thresholds accounting fo...

متن کامل

Ophthalmologic Techniques for Evaluating Glaucoma

Numerous articles describe findings from patients with known and suspected glaucoma using confocal scanning laser ophthalmoscopy (CSLO), scanning laser polarimetry (SLP), and optical coherence tomography (OCT). These studies report that abnormalities may be detected on these examinations before functional changes are noted.(1) The literature, specialty society guidelines, and clinical input ind...

متن کامل

Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma.

PURPOSE To evaluate the influence of disease severity and optic disc size on the diagnostic accuracy of three imaging technologies for structural assessment in glaucoma: confocal scanning laser ophthalmoscopy, scanning laser polarimetry, and optical coherence tomography. METHODS One hundred five patients with glaucoma and 61 normal subjects were recruited from the Diagnostic Innovations in Gl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 43 11  شماره 

صفحات  -

تاریخ انتشار 2002