Fabrication of the mandibular implant-supported fixed restoration using CAD/CAM technology: a clinical report.
نویسندگان
چکیده
The mandibular implant-supported fixed restoration is an appropriate treatment choice for patients with inadequate bone volume in the posterior mandible. Computer-aided design/computer-aided manufacturing (CAD/CAM) technology has broadened the scope and application for this treatment option. A milled titanium bar retaining individual all-ceramic zirconium oxide crowns, with composite resin replicating gingival tissues, is recommended as an acceptable variation for this type of prosthesis. An alternative method for fabricating a mandibular implant-supported fixed restoration using CAD/CAM technology is described.
منابع مشابه
Implant-supported fixed restoration of post-traumatic mandibular defect accompanied with skin grafting: A clinical report
Traumatic defects are mostly accompanied by hard and soft tissue loss. This report describes the surgical and prosthetic treatment of a patient with post-traumatic mandibular defect. A split-thickness skin graft was performed prior to implant placement and prefabricated acrylic stent was placed to hold the graft in place. The esthetic and functional demands of the patient were fulfilled by impl...
متن کاملDual jaw treatment of edentulism using implant-supported monolithic zirconia fixed prostheses.
UNLABELLED This case report describes restoration of the edentulous maxilla and mandible with implant supported fixed prostheses using monolithic zirconia, where the incisal edges and occluding surfaces were made of monolithic zirconia. Edentulism is a debilitating condition that can be treated with either a removable or fixed dental prosthesis. The most common type of implant-supported fixed p...
متن کاملFabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview
This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant pr...
متن کاملCase Report: Implant-Supported Removable Partial Denture In A Mandibular Kennedy CL II: A Clinical Report
Abstract The implant-supported removable partial dentures should be an alternative to conventional removable partial dentures and implant-supported fixed partial prostheses when the implant’s insertion is confined by bone height and thickness. Placing a single implant in the posterior region would modify the Kennedy Class II configuration to a Kennedy Class III and increase the stability a...
متن کاملCAD/CAM technology for implant abutments, crowns, and superstructures.
PURPOSE The aim of this systematic review was to compare implant prostheses fabricated by computer-assisted design and computer-assisted manufacturing (CAD/CAM) with conventionally fabricated implant prostheses when assessing esthetics, complications (biologic and mechanical), patient satisfaction, and economic factors. MATERIALS AND METHODS Electronic searches for clinical studies focusing o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of prosthetic dentistry
دوره 102 5 شماره
صفحات -
تاریخ انتشار 2009