Utility of high-resolution electroanatomic mapping of the left ventricle using a multispline basket catheter in a swine model of chronic myocardial infarction.
نویسندگان
چکیده
BACKGROUND Standard electroanatomic mapping systems use a single catheter to perform left ventricular substrate mapping. A new mapping system uses a 64-electrode mini-basket catheter to perform rapid automated acquisition of chamber geometry, voltage, and activation. OBJECTIVE The aim of this study was to compare the accuracy of electroanatomic mapping using the basket catheter with that of mapping using a standard linear catheter in a swine model of chronic myocardial infarction. METHODS Ten swine underwent left anterior descending coronary artery occlusion to create an anteroseptal myocardial infarction. Animals underwent delayed-enhancement magnetic resonance imaging (MRI) and then detailed left ventricular voltage mapping with both the basket and the linear catheter. Map characteristics and scar area were compared between the basket catheter, linear catheter, and MRI. Induced ventricular tachycardia (VT) was mapped with the basket catheter. RESULTS More points were acquired with the basket catheter than with the standard catheter (8762 ± 3164 vs 1712 ± 551; P < .001). The fifth percentile of normal bipolar voltage distribution with the basket catheter was 1.54 mV. Using a bipolar voltage cutoff of 1.5 mV, the total infarct areas measured using the basket catheter, linear catheter, and MRI were similar (17.8 cm(2) vs 20.9 cm(2) vs 17.5 cm(2); P = .69); however, the correlation between MRI and catheter scar area measurement was best for the basket catheter (basket vs linear: r = .76 vs r = .71). In 3 animals, sustained poorly tolerated VT was initiated and the circuit mapped successfully with the basket catheter in <5 minutes. CONCLUSION Rapid substrate and activation mapping using a 64-electrode mini-basket catheter allows detailed voltage and activation mapping in postinfarction cardiomyopathy. This system may be useful for substrate and VT mapping in human postinfarction cardiomyopathy.
منابع مشابه
Electroanatomic mapping of the left ventricle in a porcine model of chronic myocardial infarction with magnetic resonance-based catheter tracking.
BACKGROUND X-ray fluoroscopy constitutes the fundamental imaging modality for catheter visualization during interventional electrophysiology procedures. The minimal tissue discriminative capability of fluoroscopy is mitigated in part by the use of electroanatomic mapping systems and enhanced by the integration of preacquired 3-dimensional imaging of the heart with computed tomographic or magnet...
متن کاملCorrelation of Scar in Cardiac MRI and High‐Resolution Contact Mapping of Left Ventricle in a Chronic Infarct Model
BACKGROUND Endocardial mapping for scars and abnormal electrograms forms the most essential component of ventricular tachycardia ablation. The utility of ultra-high resolution mapping of ventricular scar was assessed using a multielectrode contact mapping system in a chronic canine infarct model. METHODS Chronic infarcts were created in five anesthetized dogs by ligating the left anterior des...
متن کاملCombined epicardial and endocardial electroanatomic mapping in a porcine model of healed myocardial infarction.
BACKGROUND Substrate mapping of post-myocardial infarction ventricular tachycardia involves electroanatomic delineation of scarred tissue on the basis of electrogram characteristics during sinus rhythm. A percutaneous transthoracic technique was recently described that allows catheter mapping of the epicardial surface of the heart. This study sought to determine whether the epicardial extent of...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملEmergence of Multielectrode Mapping
The technological imperative is changing the field of electrophysiology, and we are currently at a crossroads in complex ablation. The rapid emergence of electroanatomic mapping with multielectrode catheters was spawned out of both intellectual necessity (desire for mechanistic insights into arrhythmias) and clinical necessity (to expedite mapping time). During the 1980s, mapping with single-po...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart rhythm
دوره 12 1 شماره
صفحات -
تاریخ انتشار 2015