Corneal lenticule storage before reimplantation

نویسندگان

  • Yu-Chi Liu
  • Geraint P. Williams
  • Ben L. George
  • Yu Qiang Soh
  • Xin Yi Seah
  • Gary Swee Lim Peh
  • Gary Hin Fai Yam
  • Jodhbir S. Mehta
چکیده

Purpose To explore the optimal lenticule storage conditions that maintain lenticule integrity and clarity. Methods A total of 99 lenticules obtained from myopic patients undergoing small incision lenticule extraction (SMILE) were divided into four combinations for short-term storage conditions: PBS, Dulbecco's Modified Eagle's Medium (DMEM), Optisol GS, or anhydrous glycerol. Two thirds of the lenticules were further stored for 4 weeks under eight different conditions. Clarity evaluation with transmittance measurements, cell-death assays with terminal deoxynucleotidyl transferase-mediated nick end labeling assay (TUNEL), collagen fibril spacing and necrotic response assessed with transmission electron microscopy (TEM), and immunohistochemistry analysis for human leukocyte antigens (HLAs) and CD45 for immunogenicity, and matrix metalloproteinase (MMP)-2 for keratocyte response, were undertaken at baseline, 48 h (short term), and 4 weeks (long term). Results The TUNEL and immunogenicity results were comparable among the groups. The mean percentage of TUNEL-positive cells across all groups was 24.3% ± 11.8% and 62.9% ± 20.7% at the 48 h and 4 week time points, respectively. HLA-ABC+, HLA-DR+, and CD45+ cells were extremely rare, and MMP-2 expression ranged from non-detectable to minimal, under all conditions at all time points. Transmittance at 4 weeks was significantly different among groups with the greatest maintenance of clarity seen in the lenticules stored initially in DMEM at 4 °C for 48 h followed by cryopreservation in serum-free medium or glycerol at 4 °C followed by storage at room temperature. At TEM analysis at 4 weeks, the lenticules cryopreserved in liquid nitrogen, regardless of storage solutions, had significantly narrower inter-fibrillar distance than controls, while glycerol-preserved lenticules, at either room temperature or -80 °C, maintained the inter-fibrillar distance. Conclusions Clarity, structural integrity, and low immunogenicity under various conditions, at 4 °C or room temperature for short-term storage, offer encouragement for lenticule storage. It can be undertaken without access to s specialized and potentially expensive laboratory setup at least within the first 48 h before transportation to larger facilities for long-term storage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hyperopic refractive correction by LASIK, SMILE or lenticule reimplantation in a non-human primate model

Hyperopia is a common refractive error, apparent in 25% of Europeans. Treatments include spectacles, contact lenses, laser interventions and surgery including implantable contact lenses and lens extraction. Laser treatment offers an expedient and reliable means of correcting ametropia. LASIK is well-established however SMILE (small-incision lenticule extraction) or lenticule implantation (deriv...

متن کامل

Small incision lenticule extraction (SMILE) history, fundamentals of a new refractive surgery technique and clinical outcomes

This review summarizes the current status of the small incision lenticule extraction (SMILE) procedure. Following the early work by Sekundo et al. and Shah et al., SMILE has become increasingly popular. The accuracy of the creation of the lenticule with the VisuMax femtosecond laser (Carl Zeiss Meditec) has been verified using very high-frequency (VHF) digital ultrasound and optical coherence t...

متن کامل

Changes in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) Procedure

PURPOSE To investigate the effects of lenticule creation and subsequent corneal lenticule extraction on corneal deformation parameters during small incision lenticule extraction (SMILE) procedure. MATERIALS AND METHODS In this prospective study, 18 eyes of 10 patients (27.90 ± 7.11 years, -5.64 ± 2.45 diopters) scheduled for SMILE procedure were enrolled. Changes in the corneal deformation pa...

متن کامل

Corneal biomechanical effects: small-incision lenticule extraction versus femtosecond laser-assisted laser in situ keratomileusis.

PURPOSE To compare the biomechanical properties of the cornea after small-incision lenticule extraction (lenticule extraction group) with those after femtosecond laser-assisted laser in situ keratomileusis (femtosecond LASIK group). SETTING Tianjin Eye Hospital & Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Medical University, Tianjin, China. DESIGN Pro...

متن کامل

Comparison of different intraocular pressure measurement techniques in normal eyes and post small incision lenticule extraction

PURPOSE The purpose of the study was to determine the accuracy of intraocular pressure (IOP) measurement after small incision lenticule extraction (SMILE) using Goldmann applanation tonometry (GAT) and ocular response analyzer (ORA). METHODS This is a prospective clinical study that was conducted on 30 eyes in the interval between February 2016 and September 2016. The age of the patients rang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2017