Real-Time Placental Perfusion on Contrast-Enhanced Ultrasound and Parametric Imaging Analysis in Rats at Different Gestation Time and Different Portions of Placenta

نویسندگان

  • Yi-Jie Zhou
  • Man-Li Yuan
  • Rui Li
  • Li-Ping Zhu
  • Zhao-Hui Chen
چکیده

OBJECTIVES To quantitatively analyze placental perfusion in a rat model at different gestation time and different portions of placenta by real-time contrast-enhanced ultrasound (CEUS) and parametric imaging analysis. MATERIALS AND METHODS Sixty pregnant rats at different gestation time (15 dys,17 days and 20 days) were injected intravenously with microbubbles (5×10(5) microbubbles /ml, 1.0 ml/kg), and cadence contrast pulse sequencing (transmission frequency of 7 MHz, mechanical index 0.18) was performed. Dynamic enhancement changes in placenta at different gestation time and different portions of placenta were measured and enhancement parameters analyzed with software. Correlation between enhancement parameters and average area densities of placenta vascular compartment was compared. RESULTS The pattern and real-time sequence of enhancement in uterus and placenta were clearly depicted by CEUS. The time-to-peak enhancement was earlier in central portion than that in peripheral portion (12.30±6.33s vs 36.26±10.65 s, p = 0.005), and peak intensity of enhancement is much higher in central portion than that in peripheral portion (30.20±2.85 dB vs 20.95±6.25 dB, p = 0.000). The peak intensity of enhancement at day 15 (27.70±4.47 dB) was lower than that at day 17 (30.20±2.85 dB, p = 0.042) and at day 20 (31.85±4.41 dB, p = 0.015) of gestation. Significant correlation between average area densities of vascular compartment and the peak intensity of enhancement was identified in placenta at different gestation time (p<0.05). The average area densities of vascular compartment was higher in central portion than that in peripheral portion and has significant correlation with peak intensity of enhancement of the two potions (p<0.01). CONCLUSION CEUS is feasible to depict real-time sequence and quantitative parameters of perfusion in different portion of placenta at different gestational time in a rat model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-Time Monitoring of Placental Oxygenation during Maternal Hypoxia and Hyperoxygenation Using Photoacoustic Imaging

PURPOSE This preclinical study aimed to evaluate placental oxygenation in pregnant rats by real-time photoacoustic (PA) imaging on different days of gestation and to specify variations in placental oxygen saturation under conditions of maternal hypoxia and hyperoxygenation. MATERIAL AND METHODS Placentas of fifteen Sprague-Dawley rats were examined on days 14, 17, and 20 of pregnancy with a P...

متن کامل

Quantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging

Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...

متن کامل

P-122: Morphine Effects on Placental Layers in Wistar Rats

Background: Experiments have shown that opioid drugs abuse during pregnancy can cause a delay in the development of the placenta. In mammals, the placenta is the most important channel for the exchange of Materialss between the maternal and fetal bloods. The present study investigates the time-dependent effect of the addiction duration of maternal morphine consumption during pregnancy. Material...

متن کامل

A new method to study changes in microvascular blood volume in muscle and adipose tissue: real-time imaging in humans and rat.

We employed and evaluated a new application of contrast-enhanced ultrasound for real-time imaging of changes in microvascular blood volume (MBV) in tissues in females, males, and rat. Continuous real-time imaging was performed using contrast-enhanced ultrasound to quantify infused gas-filled microbubbles in the microcirculation. It was necessary to infuse microbubbles for a minimum of 5-7 min t...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013