Estimation of blood pressure variability from 24-hour ambulatory finger blood pressure.

نویسندگان

  • S Omboni
  • G Parati
  • P Castiglioni
  • M Di Rienzo
  • B P Imholz
  • G J Langewouters
  • K H Wesseling
  • G Mancia
چکیده

Portapres is a noninvasive, beat-to-beat finger blood pressure (BP) monitor that has been shown to accurately estimate 24-hour intra-arterial BP at normal and high BPs. However, no information is available on the ability of this device to accurately track ambulatory BP variability. In 20 ambulatory normotensive and hypertensive subjects, we measured 24-hour BP by Portapres and through a brachial artery catheter. BP and pulse interval variabilities were quantified by (1) the SDs of the mean values (overall variability) and (2) spectral power, computed either by fast Fourier transform and autoregressive modeling of segments of 120-second duration for spectral components from 0.025 to 0.50 Hz or in a very low frequency range (between 0.00003 and 0.01 Hz) by broadband spectral analysis. The 24-hour SD of systolic BP obtained from Portapres (24+/-2 mm Hg) was greater than that obtained intra-arterially (17+/-1 mm Hg, P<0.01), but the overestimation was less evident for diastolic (3+/-1 mm Hg, P<0.01) and mean (3+/-1 mm Hg, P<0.01) BP. The BP spectral power <0.15 Hz was also overestimated by Portapres more for systolic than for diastolic and mean BPs; similar findings were obtained by the fast Fourier transform, the autoregressive approach, and focusing on the broadband spectral analysis. BP spectral power >0.15 Hz obtained by the Portapres was similar during the day but lower during the night when compared with those obtained by intra-arterial recordings (P<0.01). No differences were observed between Portapres and intra-arterial recordings for any estimation of pulse interval variabilities. The overestimation of BP variability by Portapres remained constant over virtually the entire 24-hour recording period. Thus, although clinical studies are still needed to demonstrate the clinical relevance of finger BP variability, our study shows that Portapres can be used with little error to estimate 24-hour BP variabilities if diastolic and mean BPs are used. For systolic BP, the greater error can be minimized by using correction factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Ramadan fasting on ambulatory blood pressure in hypertensive patients

Background: Previous studies have indicated that Ramadan fasting has beneficial effects on cardiovascular risk factors, specially blood pressure and heart rate. In the present study, the effect of Ramadan fasting on 24-hour ambulatory blood pressure and heart rate has been investigated. Materials and Methods: This prospective observational study was conducted on two groups of individuals. Six p...

متن کامل

Birth weight influences blood pressure values and variability in children and adolescents.

The objective of the present study was to assess the relationships between birth weight and the values and variability of ambulatory blood pressure. Six hundred thirty healthy children (369 girls) age 4 to 18 years (mean, 9.9 years) born at term after a normotensive pregnancy were included. The subjects were divided into 5 groups according to birth weight. For each subject, a 24-hour ambulatory...

متن کامل

Baroreflex sensitivity inversely correlates with ambulatory blood pressure in healthy normotensive humans.

Patients with hypertension have a blunted sensitivity of baroreflex control of heart period. In these patients, baroreflex sensitivity is positively related to heart rate variability and inversely related to blood pressure variability. We hypothesized that this relationship would also be evident in healthy normotensive subjects and that individuals with higher baroreflex sensitivity would have ...

متن کامل

Factors Affecting Ambulatory Blood Pressure Reproducibility Results of the HARVEST Trial

To assess the reproducibility of ambulatory blood pressure, we recorded 24-hour blood pressure twice 3 months apart in 508 hypertensive subjects participating in the HARVEST trial using a noninvasive technique. Blood pressure was measured every 10 minutes during the daytime and 30 minutes during the nighttime. Reproducibility was better for ambulatory than for office blood pressure. It was grea...

متن کامل

Factors Affecting Ambulatory Blood Pressure Reproducibility

To assess the reproducibility of ambulatory blood pressure, we recorded 24-hour blood pressure twice 3 months apart in 508 hypertensive subjects participating in the HARVEST trial using a noninvasive technique. Blood pressure was measured every 10 minutes during the daytime and 30 minutes during the nighttime. Reproducibility was better for ambulatory than for office blood pressure. It was grea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 1998