In-vitro imaging of femoral artery nitinol stents for deformation analysis.

نویسندگان

  • Arundhuti Ganguly
  • Jeffrey Simons
  • Alex Schneider
  • Benjamin Keck
  • Nathan R Bennett
  • Rebecca Fahrig
چکیده

PURPOSE Femoral artery stents are prone to fracture, and studying their deformations could lead to a better understanding of the cause of breakage. The present study sought to develop a method of imaging and analyzing stent deformation in vitro with use of a calibrated test device. MATERIALS AND METHODS High-resolution (approximately 200 μm) volumetric data were obtained with a flat-panel detector-based C-arm computed tomography system. A nitinol stent placed in a testing device was imaged with various loads that caused bending, axial tension, and torsion. Semiautomatic software was developed to calculate the bending, extension, and torsion from the stent images by measuring the changes in the radius of curvature, eccentricity, and angular distortions. RESULTS For the axial tension case, there was generally good agreement between the physical measurements and the image-based measurements. The bending measurements had better agreement at bend angles lower than 30°. For stent torsion, the hysteresis between the loading and unloading curves were larger for the image-based results compared with physical measurements. CONCLUSIONS An imaging and analysis framework has been set up for the analysis of stent deformations that shows fairly good agreement between physical and image-based measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-vivo imaging of femoral artery nitinol stents for deformation analysis.

PURPOSE The authors have developed a direct method to study femoral artery stent deformations in vivo. A previously described imaging and analysis approach based on a calibrated phantom was used to examine stents in human volunteers treated for atherosclerotic disease. In this pilot study, forces on stents were evaluated under different in-vivo flexion conditions. MATERIALS AND METHODS The op...

متن کامل

Pilot trial of cryoplasty or conventional balloon post-dilation of nitinol stents for revascularization of peripheral arterial segments: the COBRA trial.

OBJECTIVES The purpose of this study is to compare post-dilation strategies of nitinol self-expanding stents implanted in the superficial femoral artery of diabetic patients with peripheral arterial disease. BACKGROUND Endovascular treatment of superficial femoral artery disease with nitinol self-expanding stents is associated with high rates of in-stent restenosis in patients with diabetes m...

متن کامل

Drug-Coated Balloons for Long Superficial Femoral Artery Disease: Leaving Nothing Behind in the Real-World.

SEE PAGE 950 T he optimal endovascular strategy for treatment of superficial femoral artery (SFA) atherosclerotic disease is an evolving area of research and clinical practice. Initial randomized trials demonstrated a benefit of nitinol self-expanding stent placement in this region when compared to standalone balloon angioplasty (1). However, observational studies subsequently raised concerns r...

متن کامل

Comparison of second-generation stents for application in the superficial femoral artery: an in vitro evaluation focusing on stent design.

PURPOSE To examine and compare in an ex vivo study different nitinol stent designs intended for the superficial femoral artery (SFA) with regard to the appearance of fracture. METHODS Seven different 8-×40-mm nitinol stents were evaluated (Misago, Absolute, Smart, Luminexx, Sentinol, Lifestent NT, and Sinus-Superflex). Finite element analysis (FEA) was used for digitalized stent design compar...

متن کامل

Carotid artery stents: in vitro comparison of different stent designs and sizes using CT angiography and contrast-enhanced MR angiography at 1.5T and 3T.

BACKGROUND AND PURPOSE CT angiography (CTA) and MR angiography (MRA) are increasingly used methods for evaluation of stented vessel segments. Our aim was to compare CTA, contrast-enhanced MRA (CE-MRA) at 1.5T, and CE-MRA at 3T for the visualization of carotid artery stents and to define the best noninvasive imaging technique as an alternative to conventional angiography for each stent. MATERI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular and interventional radiology : JVIR

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2011