Improving the quality of coronary bypass surgery with intraoperative angiography: validation of a new technique.
نویسندگان
چکیده
OBJECTIVES We report a comprehensive assessment and validation of a new intraoperative angiography technique. BACKGROUND Technical problems at the site of the distal anastomosis compromise an underappreciated proportion of coronary bypass grafts. The absence of a systematic, validated technique to verify graft patency in the operating room represents a significant breach in quality assurance. METHODS Fluorescent indocyanine green (ICG) dye is excited with dispersed laser light to create an angiographic depiction of the graft, native vessel, and anastomosis. One-hundred twenty patients underwent ICG angiography. Angiograms were reviewed for reliability and validity studies. RESULTS A total of 348 coronary bypass grafts were studied. Each ICG angiogram took 2.2 +/- 1.1 min to perform. The ICG angiography found 4.2% of patients had significant graft problems requiring major revision. Quality of visualization was rated according to a seven-point Likert scale (1 = worst, 7 = best). Among conduits, saphenous veins were best visualized (mean score +/- standard deviation), 6.4 +/- 1.5 versus 5.5 +/- 1.9 for internal mammary arteries and 4.4 +/- 2.3 for radial arteries (p = 0.02). Location of distal anastomosis did not influence quality of visualization. There was high inter-rater reliability for graft revision (kappa = 1.0) and graft patency (kappa = 0.97) between surgeons. Sensitivity and specificity of the ICG angiograms for graft stenosis >50% was 100% among 22 grafts also studied with X-ray angiography. CONCLUSIONS Information from ICG angiograms led to graft revisions for technical problems in 4.2% of patients that would have otherwise gone unrecognized. Intraoperative angiography is an emerging tool for improving the quality of coronary bypass surgery.
منابع مشابه
Cardiac Surgery mproving the Quality of Coronary ypass Surgery With Intraoperative Angiography alidation of a New Technique
OBJECTIVES We report a comprehensive assessment and validation of a new intraoperative angiography technique. BACKGROUND Technical problems at the site of the distal anastomosis compromise an underappreciated proportion of coronary bypass grafts. The absence of a systematic, validated technique to verify graft patency in the operating room represents a significant breach in quality assurance. M...
متن کاملHow I do it: high-quality intraoperative fluorescence imaging in off-pump coronary artery bypass grafting.
We have developed a simple technique for establishing high-quality intraoperative fluorescence imaging in off-pump coronary artery bypass grafting. The technique of transaortic injection of indocyanine green is an effective method of achieving clear fluorescence imaging and for evaluating the quality of graft anastomoses. We consider the images obtained with this technique to be equivalent to t...
متن کاملEffect of Cardiac Rehabilitation Program on Quality of Sleep in Patients with Coronary Artery Bypass Graft Surgery
800x600 Background and Objectives: Poor sleep quality is a common problem among patients with coronary artery bypass surgery. The aim of this study was to assess the effect of cardiac rehabilitation program on improving quality of sleep in patients with poor sleep quality after coronary bypass surgery. Materials and Methods: This was a quasi-experimental study. Fr...
متن کاملRoutine intraoperative angiography improves the early patency of coronary grafts performed on the beating heart.
OBJECTIVES The techniques of performing coronary revascularization without cardiopulmonary bypass are rapidly evolving. However, concern remains regarding the accuracy of coronary artery anastomoses performed on the beating heart. This report reviews the use of intraoperative angiography in the critical appraisal of "off-pump" coronary artery bypass graft (CABG) surgery. PATIENTS Intraoperati...
متن کاملPii: S1010-7940(99)00273-0
Objectives: The most important determinant for the success of minimally invasive coronary artery bypass grafting (MIDCAB) is the quality and long-term patency of the graft and anastomosis. Intra and postoperative quality assessment is important to con®rm the safety and effectiveness of minimally invasive techniques. Methods: From January to December 1998 MIDCAB was performed in 246 patients usi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 46 8 شماره
صفحات -
تاریخ انتشار 2005