Assessment of anterior and posterior corneal indices using two Scheimpflug analyzers.
نویسندگان
چکیده
PURPOSE To assess the agreement between the elevation and curvature measurements of the anterior and posterior corneal surfaces obtained using the Galilei Dual Scheimpflug Analyzer and those obtained using the Pentacam single Scheimpflug system. METHODS This prospective, noninterventional, diagnostic study was conducted at the Department of Ophthalmology at the American University of Beirut (Medical Center) and included 60 eyes of 60 consecutive patients. Measurements were obtained using 2 different Scheimpflug analyzers (Galilei and Pentacam). The best-fit sphere was set at 8 mm in both machines. Pachymetry (CCT), anterior elevation (AE) and posterior elevation (PE), and curvature were assessed. Pearson's correlation coefficients, comparison of means, and Bland-Altman plots were used to evaluate agreement between the 2 systems. RESULTS The average CCT (at the corneal apex) was 533 ± 35 µm and 532 ± 37 µm (p=0.980), the average central AE was 1.25 ± 3.95 µm and 2.29 ± 5.28 µm (p=0.964), and the average central PE was 4.19 ± 8.18 µm and 5.42 ± 14.05 (p=0.956) µm with the Galilei and Pentacam, respectively. CONCLUSION The Scheimpflug analyzers correlated well in the assessment of pachymetry, elevation, and curvature.
منابع مشابه
Comparison between Two Scheimpflug Anterior Segment Analyzers
PURPOSE To compare the anterior segment indices measured by two Scheimpflug camera machines; Galilei and Pentacam. METHODS In this observational case series, the anterior segment indices of myopic healthy subjects seeking for refractive surgery were measured by Pentacam and Galilei on the same day. Analyzed parameters were anterior and posterior best fit spheres (BFS), axial curvature, true c...
متن کاملRefractive correction method for digital charge-coupled device-recorded Scheimpflug photographs by means of ray tracing.
Our purpose is to correct digital CCD-recorded Scheimpflug photographs, imaging both the anterior and posterior corneal surface, the anterior chamber, and the anterior eye lens surface for optical distortions. In a ray-tracing algorithm the imaging of the posterior corneal surface in a given Scheimpflug photograph is corrected by applying Snell's law on parallel incident rays entering through t...
متن کاملPosterior corneal astigmatism.
In the optical system of the human eye, total refractive power consists mainly of corneal and lenticular components. Approximately two-thirds of the eye's converging power is at the air–cornea (tear film) interface; one-third is in the lens. Total corneal power is determined by corneal anterior and posterior curvature, corneal thickness, and the corneal refractive indices. Traditionally, anteri...
متن کاملMeasuring Corneal Haze by Using Scheimpflug Photography and Confocal Microscopy
PURPOSE We compared corneal backscatter estimated from a Scheimpflug camera with backscatter estimated from a clinical confocal microscope across a wide range of corneal haze. METHODS A total of 59 corneas from 35 patients with a range of severity of Fuchs' endothelial corneal dystrophy and 15 corneas from 9 normal participants were examined using a Scheimpflug camera (Pentacam) and a confoca...
متن کاملEvaluation of Anterior Segment Parameters and Possible Influencing Factors in Normal Subjects Using a Dual Scheimpflug Analyzer
PURPOSE To investigate normal anterior segment parameters and analyze the possible influencing factors using a dual Scheimpflug system. SETTING Department of Ophthalmology, Affiliated Sixth People's Hospital Shanghai Jiao Tong University, Shanghai, China. DESIGN A prospective observational case series. METHODS A total of 153 normal subjects (153 eyes) were studied. The anterior segment pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 77 1 شماره
صفحات -
تاریخ انتشار 2014