Sensitive and reproducible intact mass analysis of complex protein mixtures with superficially porous capillary reversed-phase liquid chromatography mass spectrometry.
نویسندگان
چکیده
The compatibility of superficially porous (SP) resin for label-free intact protein analysis with online capillary LC/MS is demonstrated to give improved chromatographic resolution, sensitivity, and reproducibility. The robustness of the platform was measured against several samples of varying complexity and sample loading amount. The results indicate that capillary SP columns provide high loading capacities and that ∼6 s chromatographic peak widths are typical for standard proteins in simple mixtures and proteins isolated from cell and tissue lysates. Subfemtomole detection limits for standard proteins were consistently observed, with the lowest levels at 12 amol for ubiquitin. The analysis of total heart homogenates shows that capillary SP columns provide theoretical peak capacity of 106 protein forms with 30 min total analysis time and enabled detection of proteins from complex mixtures with a single high-resolution scan. The SPLC/MS platform also detected 343 protein forms from two HeLa acid extract replicate analyses that consumed 5 × 10(4) cells and 30 min analysis time, each. Comparison of all the species observed in each HeLa replicate showed 90% overlap (309 forms) with a Pearson correlation coefficient of 89.9% for the common forms observed in the replicates. Efficient acid extract of 1 × 10(4) HeLa cells allowed reproducible detection of common modification states and members from all five of the histone families and demonstrated that capillary SPLC/MS supports reproducible label-free profiling of histones in <15 min total analysis time. The data presented demonstrate that a capillary LC/MS platform utilizing superficially porous stationary phase and a LTQ-Orbitrap FT-MS is fast, sensitive, and reproducible for intact protein profiling from small tissue and cell amounts.
منابع مشابه
In-Line Separation by Capillary Electrophoresis Prior to Analysis by Top-Down Mass Spectrometry Enables Sensitive Characterization of Protein Complexes
Intact protein analysis via top-down mass spectrometry (MS) provides a bird's eye view over the protein complexes and complex protein mixtures with the unique capability of characterizing protein variants, splice isoforms, and combinatorial post-translational modifications (PTMs). Here we applied capillary electrophoresis (CE) through a sheathless CE-electrospray ionization interface coupled to...
متن کاملOptions for rapid analysis of peptides and proteins, using wide-pore, superficially porous, high-performance liquid chromatography particles with unique bonded-phase ligands.
The large size and complexity of many proteins constrains the reversed-phase high-performance liquid chromatography packings that are useful for their separation. Wide-pore, superficially porous, silica-based packings with solid 4.5-microm cores and a 0.25-microm porous outer layer (Poroshell) demonstrate a variety of characteristics that are beneficial for the separation of proteins. A shorter...
متن کاملUltrafast reversed-phase high-performance liquid chromatographic separations: an overview.
Ultrafast reversed-phase high-performance liquid chromatographic (HPLC) separations are often needed for analyses related to combinatorial chemistry, studies in liquid chromatography-mass spectrometry, and other applications in which very rapid sample turnaround is paramount. Unfortunately, no consensus exists regarding the best column technology for optimally performing the desired rapid separ...
متن کاملMultidimensional separations for protein/peptide analysis in the post-genomic era.
Proteomics is the study of all or part of the protein complement of genes in an organism, often involving the analysis of complex protein/peptide samples. Such complex samples are beyond the separation capacity of 1-D separation techniques. This review describes several multidimensional separations for proteins and peptides. First, several variants of 2-D liquid chromatography (2DLC) are review...
متن کاملA multidimensional differential proteomic platform using dual-phase ion-exchange chromatography-polyacrylamide gel electrophoresis/reversed-phase liquid chromatography tandem mass spectrometry.
Differential proteomic analysis has arisen as a large-scale means to discern proteome-wide changes upon treatment, injury, or disease. Tandem protein separation methods are required for large-scale differential proteomic analysis. Here, a novel multidimensional platform for resolving and differentially analyzing complex biological samples is presented. The platform, collectively termed CAX-PAGE...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 83 24 شماره
صفحات -
تاریخ انتشار 2011