Biomechanical comparison of endplate forces generated by uniaxial screws and monoaxial pedicle screws.

نویسندگان

  • David A Essig
  • Christopher P Miller
  • Ming Xiao
  • Paul Ivancic
  • Kola Jegede
  • Raghav Badrinath
  • Brian G Smith
  • Jonathan N Grauer
چکیده

Current surgical treatment of idiopathic scoliosis involves the use of various segmental instrumentation. Various pedicle screws have allowed for improved correction. Although monoaxial screws have improved rotational control compared with polyaxial screws, their use may increase screw-bone interface or vertebral endplate forces if not inserted in an exactly straight trajectory. Uniaxial screws potentially decrease these forces while retaining the advantages of monoaxial screws with respect to better rotational control. The purpose of this study was to compare the vertebral endplate forces with monoaxial or uniaxial screws when being reduced to a rod. Thirty-two plastic, surrogate T11 vertebrae were prepared with monoaxial (n=16) or uniaxial (n=16) screws. Screw angles relative to inferior vertebral endplates were assessed with lateral radiographs. The vertebrae were fixed to a load cell, and loads were measured as the screw was reduced to a rod. Monoaxial screws demonstrated a linear progression of endplate force with increasing screw angle. Uniaxial screws demonstrated minimal endplate force until approximately 20°, coinciding with screwhead excursion angle. As this maximum excursion angle was passed, uniaxial screws demonstrated a force slope similar to the monoaxial screws.The measured endplate forces should be equivalent to forces at the screw-bone interface. The reduced force with uniaxial screws is expected to have less cranial-caudal plow potential as the screw is coupled to a rod for deformity correction. This could have potential implications for screw failure, especially in less dense bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monoaxial Pedicle Screws Are Superior to Polyaxial Pedicle Screws and the Two Pin External Fixator for Subcutaneous Anterior Pelvic Fixation in a Biomechanical Analysis

Purpose. Comparison of monoaxial and polyaxial screws with the use of subcutaneous anterior pelvic fixation. Methods. Four different groups each having 5 constructs were tested in distraction within the elastic range. Once that was completed, 3 components were tested in torsion within the elastic range, 2 to torsional failure and 3 in distraction until failure. Results. The pedicle screw system...

متن کامل

Design and biomechanical study of a modified pedicle screw.

OBJECTIVE In pedicle screw fixation, the heads of monoaxial screws need to be directed in the same straight line to accommodate the rod placement by backing out during operation, which decreases the insertional torque and internal fixation strength. While polyaxial screws facilitate the assembly of the connecting rod, but its ball-in-cup locking mechanism reduces the static compressive bending ...

متن کامل

Biomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support

BACKGROUND Lumbosacral fusion is a relatively common procedure that is used in the management of an unstable spine. The anterior interbody cage has been involved to enhance the stability of a pedicle screw construct used at the lumbosacral junction. Biomechanical differences between polyaxial and monoaxial pedicle screws linked with various rod contours were investigated to analyze the respecti...

متن کامل

Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review

OBJECTIVES No studies have compared monoaxial and polyaxial pedicle screws with regard to the von Mises stress of the instrumentation, intradiscal pressures of the adjacent segment and adjacent segment degeneration. METHODS Short-segment monoaxial/polyaxial pedicle screw fixation techniques were compared using finite element methods, and the redistributed T11-L1 segment range of motion, large...

متن کامل

An Innovative Universal Screw Removal Instrument

OBJECTIVE To present the clinical benefits of an instrument designed to facilitate removal of polyaxial screws during revision surgery. METHODS All polyaxial screws can be removed without additional materials or a large amount of debridement using our newly designed instrument. Forty-two screws were removed from five patients without any complications using this instrument. RESULTS We remov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 10  شماره 

صفحات  -

تاریخ انتشار 2012