Effects of Ankle Arthrodesis on Biomechanical Performance of the Entire Foot
نویسندگان
چکیده
BACKGROUND/METHODOLOGY Ankle arthrodesis is one popular surgical treatment for ankle arthritis, chronic instability, and degenerative deformity. However, complications such as foot pain, joint arthritis, and bone fracture may cause patients to suffer other problems. Understanding the internal biomechanics of the foot is critical for assessing the effectiveness of ankle arthrodesis and provides a baseline for the surgical plan. This study aimed to understand the biomechanical effects of ankle arthrodesis on the entire foot and ankle using finite element analyses. A three-dimensional finite element model of the foot and ankle, involving 28 bones, 103 ligaments, the plantar fascia, major muscle groups, and encapsulated soft tissue, was developed and validated. The biomechanical performances of a normal foot and a foot with ankle arthrodesis were compared at three gait instants, first-peak, mid-stance, and second-peak. PRINCIPAL FINDINGS/CONCLUSIONS Changes in plantar pressure distribution, joint contact pressure and forces, von Mises stress on bone and foot deformation were predicted. Compared with those in the normal foot, the peak plantar pressure was increased and the center of pressure moved anteriorly in the foot with ankle arthrodesis. The talonavicular joint and joints of the first to third rays in the hind- and mid-foot bore the majority of the loading and sustained substantially increased loading after ankle arthrodesis. An average contact pressure of 2.14 MPa was predicted at the talonavicular joint after surgery and the maximum variation was shown to be 80% in joints of the first ray. The contact force and pressure of the subtalar joint decreased after surgery, indicating that arthritis at this joint was not necessarily a consequence of ankle arthrodesis but rather a progression of pre-existing degenerative changes. Von Mises stress in the second and third metatarsal bones at the second-peak instant increased to 52 MPa and 34 MPa, respectively, after surgery. These variations can provide indications for outcome assessment of ankle arthrodesis surgery.
منابع مشابه
Anterior Ankle Arthrodesis with Molded Plate: Technique and Outcomes
Background: There is still controversy regarding the best technique for ankle arthrodesis to acheive stable rigid fixation along with reconstructing a functional plantigrade foot. Moreover, existing techniques have complictions related to stability, soft tissue covering, fusion rate, and exposure. Methods: With the anterior approach exactly on the tibialis anterior sheath, the joint was expose...
متن کاملAdjacent Joint Kinematics After Ankle Arthrodesis During Cadaveric Gait Simulation.
BACKGROUND Arthrodesis is an effective and reliable treatment for end-stage ankle arthritis; however, many patients develop ipsilateral adjacent joint arthritis following surgery. The mechanism that drives adjacent joint arthritis remains uncertain. Cadaveric simulation permits direct investigation of the effects of both arthrodesis and movement strategy on adjacent joints during simulated walk...
متن کاملThe Effects of Modified Ankle Foot Orthosis on balance in Healthy Older People
Introduction: Balance impairment and related injuries are common in elderly and patients with neurologic disorders. Ankle foot orthosies can influence on balance via improvement of movement disorders. Therefore the aim of this study was to investigate the effects of modified ankle-foot orthosis on balance performance in healthy elderly. Materials & Methods: The research was conducted on ten ...
متن کاملBiomechanical comparison of first metatarsophalangeal joint arthrodeses using triple-threaded headless screws versus partially threaded lag screws.
BACKGROUND Triple-threaded, cannulated headless screws of varying thread diameters and pitch are designed to maintain thread length across the arthrodesis plane, provide joint compression, and reduce countersinking. This study tested the biomechanical fixation strength of conventional partially threaded lag screws compared to triple-threaded headless screws in first metatarsophalangeal joint ar...
متن کاملComparing the Effects of Flexible and Rigid Ankle-Foot Orthoses on Balance/Walking Performance in Individuals With Multiple Sclerosis
Background: Ankle-Foot orthoses are used to minimize the impact of weakness in ankle dorsiflexion muscles. The study on different orthotic types defines the optimal design, which effectively improves the users’ mobility. This study investigated the potential benefits and risks of a Dictus-band (flexible orthotic), compared with a thermoplastic (fixed) ankle-foot orthosis on the mobility of indi...
متن کامل