BACKGROUND AND PURPOSE Histopathologic analysis was performed to better understand quantity, particle size, and composition of embolized debris collected in protection filters during carotid artery stent implantation. METHODS Elective carotid stent implantation with the use of a distal filter protection was attempted in 38 consecutive lesions (36 patients) of the internal carotid artery presenting >70% diameter stenosis (mean, 82.1+/-11.1%). Mean age of the patients was 70.7+/-7.7 years; 75% were men, and 50% of patients had previous neurological symptoms. RESULTS In 37 lesions (97.4%) it was possible to position the filter device, and in all lesions a stent was successfully implanted. The only complication occurring in the hospital and during the 30-day follow-up was 1 death due to acute myocardial infarction. Neurological sequelae did not occur. Histomorphometric analysis was performed on the filters. Presence of debris was detected in 83.7% of filters. The mean surface area of the polyurethane membrane filter covered with material was 53.2+/-19.8%. Particle size ranged from 1.08 to 5043.5 microm (mean, 289.5+/-512 microm) in the major axis and 0.7 to 1175.3 microm (mean, 119.7+/-186.7 microm) in the minor axis. Collected debris consisted predominantly of thrombotic material, foam cells, and cholesterol clefts. CONCLUSIONS By the use of distal protection filters during carotid artery stenting, it was possible to collect particulate debris potentially leading to distal vessel occlusion in a high percentage of cases. Qualitative analysis of embolized material showed debris dislocated during the percutaneous intervention from atheromatous plaques.
منابع مشابه
ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES
Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...
متن کاملCerebral protection with filter devices during carotid artery stenting.
BACKGROUND Distal embolization of debris during percutaneous carotid artery stenting may result in neurological deficit. Filter devices for cerebral protection potentially reduce the risk of embolization. METHODS AND RESULTS Elective carotid stent implantation using 3 different types of distal filter protection devices was attempted in 88 consecutive lesions (84 patients) in the internal caro...
متن کاملIntracranial internal carotid artery stenosis with vulnerable plaques successfully treated by stenting under cerebral protection.
Percutaneous transluminal angioplasty with stenting (PTA/stenting) for intracranial atherosclerotic stenoses is usually performed without any protection devices. We report a unique case of atherothrombotic stenosis with the vulnerable plaque in the cavernous portion of the internal carotid artery (ICA), which was successfully treated by PTA/stenting under cerebral protection with the flow rever...
متن کاملObservation of the embolus protection filter for Carotid Artery Stenting.
BACKGROUND Carotid artery stenting in patients with high surgical risk is considered as an effective alternative to carotid endarterectomy. Because the occurrence of distal embolization with CAS is still a major concern, an embolus protection device is usually used during the procedure. We developed a technique for observation of embolus protection filter and evaluated the debris or thrombus mi...
متن کاملCarotid artery stenting with proximal cerebral protection for patients with angiographic appearance of string sign.
OBJECTIVES The aim of this study was to assess the safety and effectiveness of carotid artery stenting (CAS) with proximal cerebral protection in patients showing string sign at carotid angiography. BACKGROUND Presence of string sign is a well-known factor for adverse events in patients with severe carotid artery disease undergoing CAS. METHODS We used retrospective analysis of a cohort of ...