Quick-EXAFS implementation on the general purpose EXAFS beamline at ESRF
نویسندگان
چکیده
The new implementation of QEXAFS acquisition on the general purpose EXAFS beamline BM29 at the European Synchrotron Radiation Facility is presented. By adopting a continuous-scan mode, a high signal-to-noise ratio can be maintained, together with a fixed exit beam and full compatibility with step-by-step operation, while reducing acquisition times to a few seconds. The new equipment implemented on the beamline is described and the potential of this application is demonstrated with a few examples.
منابع مشابه
The time-resolved and extreme conditions XAS (TEXAS) facility at the European Synchrotron Radiation Facility: the general-purpose EXAFS bending-magnet beamline BM23
BM23 is the general-purpose EXAFS bending-magnet beamline at the ESRF, replacing the former BM29 beamline in the framework of the ESRF upgrade. Its mission is to serve the whole XAS user community by providing access to a basic service in addition to the many specialized instruments available at the ESRF. BM23 offers high signal-to-noise ratio EXAFS in a large energy range (5-75 keV), continuou...
متن کاملA new detector for sub-millisecond EXAFS spectroscopy at the European Synchrotron Radiation Facility
A new FReLoN (Fast-Readout Low-Noise) high-frame-rate detector adopted for the fast continuous collection of X-ray absorption spectra is presented. The detector is installed on the energy-dispersive X-ray absorption beamline ID24 at the ESRF and is capable of full time-resolved EXAFS spectra collection with over 4 kHz repetition rate and 0.2 ms exposure time. An example of the in situ kinetic s...
متن کاملMicrobial Reduction of Hexavalent Chromium
Publication 1. A. Manceau et al, “Quantitative Zn speciation in smelter-contaminated soils by EXAFS spectroscopy,” Am. J. Sci. (in press, 2000). Figure 3 (top) Soil samples were taken at several depths from a contaminated site. (bottom) Model compounds derived from polarized-EXAFS data at the ESRF and μ-EXAFS data at the ALS provide a good fit with powder-EXAFS spectra from a soil sample, there...
متن کاملScanning and Energy Dispersive EXAFS Studies of Nickel Alkene Oligomerisation Catalysts
In situ EDE and scanning EXAFS studies of homogeneous aikene oligomerisation catalysts are reported. EDE spectra were acquired either on Station 9.3 at the SRS Daresbury Laboratory using a bent Si(220) crystal monochromator (Ni and Br K-edges) or on ID24 at the ESRF using a Si(ll1) monochromator in a Bragg geometry (Ni K-edge). The catalysts studied were derived fiom mixtures of Ni(acach (acac ...
متن کاملSAMBA: The 4–40 keV X-ray absorption spectroscopy beamline at SOLEIL
The SAMBA X-ray Absorption beamline has been operating for users since January 2008. The beamline covers a large energy range from 4 up to 40 keV in two working modes: a “high flux” mode using a sagittally focusing monochromator and a “time-resolved” mode using a dedicated Quick-EXAFS monochromator. Herein a technical description of the main beamline components is given and results concerning e...
متن کامل