Is There a Benefit to Highly Crosslinked Polyethylene in Posterior-stabilized Total Knee Arthroplasty? A Randomized Trial.
نویسندگان
چکیده
BACKGROUND Polyethylene wear and osteolysis remain a concern with the use of modular, fixed-bearing total knee arthroplasty (TKA). A variety of highly crosslinked polyethylenes (XLPs) have been introduced to address this problem, but there are few data on the results and complications of this polyethylene in posterior-stabilized knee prostheses. QUESTIONS/PURPOSES In a randomized prospective study design comparing standard polyethylene (SP) tibial inserts with XLP inserts, we asked the following questions: (1) Are there any differences in the clinical results (as measured by the classic Knee Society scoring system) and radiographic results (as measured by an evaluation for radiolucencies and osteolysis) between these groups? (2) What is the frequency of reoperation in these two groups? (3) Are there any specific complications related to XLP liners? METHODS These are preliminary data from a single surgeon of a planned interim analysis of a prospective randomized study of one modular posterior-stabilized TKA. One hundred ninety-two patients (236 knees) were randomized to receive a SP compression-molded liner or a XLP (6.5 CGy electron beam-irradiated and remelted) polyethylene liner. There was no difference in the number of knees who were lost or refused followup (14 knees [13%] with XLP and 21 knees [17%] with SP). Patients were evaluated clinically using the original Knee Society scores, Lower Extremity Activity Score (LEAS), presence of knee effusion, and by standard radiographs for radiolucent lines and osteolytic lesions. This analysis was performed at a mean followup of 4.5 years (range, 2-8 years). RESULTS There were no clinical differences between 99 knees with SP and 94 knees with XLP in original Knee Society total score (SP mean 95, SD 5; XLP mean 94, SD 7 [p = 0.16]); change in total score (SP mean 41, 95% confidence interval [CI], 39-41; XLP mean 43, 95% CI, 39-48 [p = 0.56]); knee function score (SP mean 64 [SD 25]; XLP mean 64 [SD 24] p = 0.98; change in function score (SP mean 22, 95% CI, 17-27; XLP mean 21, 95% CI, 17-27 [p = 0.79]); LEAS score (both SP and XLP 9 [SD 2]; p = 0.88); and change in LEAS (both SP and XLP mean 1, 95% CI, 1-2 [p = 0.0.38]). There were no differences, with the numbers available, in the presence of effusion (two of 94 XLP and five of 99 SP) with 2 years minimum followup. There were no differences in the frequency of radiolucent lines (13 knees with SP and 15 with XLP) or of osteolysis (two knees with SP and none with XLP). There was no difference in frequency of reoperation between the two groups (three infections in 110 knees allocated to the XLP group and five (two infections, one femoral loosening, one instability, one fracture plating) in 122 knees allocated to the standard group. There were no complications related to the XLP liner. CONCLUSIONS In this interim analysis, with the numbers available, there were no complications, but no advantages, related to the use of this XLP tibial liner. Additional enrollment has continued, and longer followup of these patients will be necessary to determine whether long-term wear characteristics differ between the groups. LEVEL OF EVIDENCE Level I, therapeutic study.
منابع مشابه
Retention of the posterior cruciate ligament versus the posterior stabilized design in total knee arthroplasty: a prospective randomized controlled clinical trial
BACKGROUND Prosthetic design for the use in primary total knee arthroplasty has evolved into designs that preserve the posterior cruciate ligament (PCL) and those in which the ligament is routinely sacrificed (posterior stabilized). In patients with a functional PCL the decision which design is chosen depends largely on the favour and training of the surgeon.The objective of this study is to de...
متن کاملNontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty
A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated...
متن کاملEleven-year implant survival rates of the all-polyethylene and metal-backed modular Optetrak posterior stabilized knee in bilateral simultaneous cases.
A prospective randomized study was conducted to determine if a design change in the articular surface geometry introduced in the Optetrak total knee to increase prosthetic joint conformity and further reduce polyethylene stress had any impact on implant survival, particularly when the all-polyethylene version of the implant was used. Forty-seven patients undergoing bilateral simultaneous total ...
متن کاملPolyethylene Tibial Post Fracture in a Posterior Stabilized (Genesis II) Total Knee Arthroplasty
Posterior stabilizing knee prostheses have been increasing in popularity recently due to some studies showing excellent long-term survivorship, more consistent kinematics, technical ease, and higher range of motion.1,2 The posterior stabilized knee relies on a cam and post mechanism to replicate native femoral rollback. One of the major potential complications of this system is post fracture. T...
متن کاملPolyethylene wear particles in synovial fluid after total knee arthroplasty.
The aims of the current study were to examine polyethylene particles in synovial fluid at an early stage, and to compare a newly introduced medial pivot total knee prosthesis with an established posterior-stabilized total knee prosthesis. Synovial fluid was obtained 1 year after knee arthroplasty from 17 patients with well-functioning prostheses (22 knees, 11 posterior-stabilized prostheses and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical orthopaedics and related research
دوره 474 1 شماره
صفحات -
تاریخ انتشار 2016