"Cyclodiode": results of a standard protocol.
نویسندگان
چکیده
AIMS To analyse the results of intraocular pressure (IOP) reduction in refractory glaucoma following diode laser cyclophotocoagulation with a repeatable standard protocol. METHODS 58 eyes of 53 patients were followed for 6-37 months (mean 19 months) after initial cyclodiode treatment. RESULTS Mean (SD) pretreatment IOP for the 58 eyes was 33.0 mm Hg (10.7) reducing at final index visit to 16.7 mm Hg (7.8) (p < 0.0001). The mean antiglaucoma medication score per eye was significantly reduced from 2.4 (0.8) to 1.4 (1.0) at last index visit (p < 0.0001) with 91% of patients able to stop oral acetazolamide. 45% of eyes required more than one treatment and the overall mean per eye was 1.6 (range 1-5). Of eyes with visual acuity 6/60 or better pretreatment, 12 (32%) lost more than two lines of Snellen acuity and two eyes with poorer acuity initially dropped to NPL. Poor visual outcome was associated with the presence of diabetic retinopathy. Hypotony (IOP < 5 mm Hg) was noted in two eyes at the last index visit although neither had specific signs of the same. No phthisis was seen. CONCLUSION The simple treatment protocol, repeated if necessary, appears relatively safe and effective at lowering IOP in eyes with refractory glaucoma.
منابع مشابه
Cyclodiode laser therapy for painful, blind glaucomatous eyes.
AIMS To determine the ability of cyclodiode laser treatment to relieve discomfort in painful blind glaucomatous eyes. METHODS 30 eyes underwent cyclodiode to reduce intraocular pressure (IOP) and relieve pain. Patients graded their pre-cyclodiode and post-cyclodiode pain. RESULTS After a minimum follow up of 6 months, a single cyclodiode treatment lowered mean IOP from 51 mm Hg (95% CI plus...
متن کاملA Comparison between Tube Surgery, ND:YAG Laser and Diode Laser Cyclophotocoagulation in the Management of Refractory Glaucoma
PURPOSE To compare the results of intraocular pressure (IOP) reduction by 3 treatment modalities, (a) glaucoma tube implants, (b) noncontact YAG laser cyclophotocoagulation (cycloYAG), and (c) contact transscleral diode laser cyclophotocoagulation (cyclodiode), in cases of advanced glaucoma refractory to alternative treatments. METHODS A consecutive group of 45 eyes that received cycloYAG wer...
متن کاملA retrospective analysis of long-term outcomes following a single episode of transscleral cyclodiode laser treatment in patients with glaucoma
OBJECTIVES To investigate the efficacy of a single cyclodiode laser photocoagulation treatment for refractory glaucoma and its effect on visual outcome in patients with good visual potential as well as to evaluate possible predictive factors in establishing optimal treatment parameters. DESIGN Retrospective observational study. SETTING Tertiary referral centre. PARTICIPANTS The notes of 8...
متن کاملTransscleral diode laser cycloablation in patients with good vision.
PURPOSE To investigate the effect of diode laser cyclophotocoagulation for glaucoma on central visual function in patients with good visual acuity (VA). PATIENTS AND METHODS Patients with preoperative VA 20/60 or better who had undergone cyclodiode treatment according to a standard protocol were evaluated retrospectively. The primary outcome variable was a recorded loss of two or more Snellen...
متن کاملP-154: Comparison of Pregnancy Outcome between Low Dose HCG in Late Follicular Phase in GnRH Long Protocol and Standard Long Protocol in ART Cycles
Background: A safe, simple and cost-effective protocol is important goal in ART cycles. The aim of this prospective study was whether administration of low dose HCG in late follicular phase can be used clinically to replace gonadotropins administration in GnRH long protocol. Materials and Methods: 69 patients who were candidate for assisted reproductive technology (ART) enrolled the study and r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 83 3 شماره
صفحات -
تاریخ انتشار 1999