Reliable quantification of BOLD fMRI cerebrovascular reactivity despite poor breath-hold performance☆

نویسندگان

  • Molly G. Bright
  • Kevin Murphy
چکیده

Cerebrovascular reactivity (CVR) can be mapped using BOLD fMRI to provide a clinical insight into vascular health that can be used to diagnose cerebrovascular disease. Breath-holds are a readily accessible method for producing the required arterial CO2 increases but their implementation into clinical studies is limited by concerns that patients will demonstrate highly variable performance of breath-hold challenges. This study assesses the repeatability of CVR measurements despite poor task performance, to determine if and how robust results could be achieved with breath-holds in patients. Twelve healthy volunteers were scanned at 3 T. Six functional scans were acquired, each consisting of 6 breath-hold challenges (10, 15, or 20 s duration) interleaved with periods of paced breathing. These scans simulated the varying breath-hold consistency and ability levels that may occur in patient data. Uniform ramps, time-scaled ramps, and end-tidal CO2 data were used as regressors in a general linear model in order to measure CVR at the grey matter, regional, and voxelwise level. The intraclass correlation coefficient (ICC) quantified the repeatability of the CVR measurement for each breath-hold regressor type and scale of interest across the variable task performances. The ramp regressors did not fully account for variability in breath-hold performance and did not achieve acceptable repeatability (ICC<0.4) in several regions analysed. In contrast, the end-tidal CO2 regressors resulted in "excellent" repeatability (ICC=0.82) in the average grey matter data, and resulted in acceptable repeatability in all smaller regions tested (ICC>0.4). Further analysis of intra-subject CVR variability across the brain (ICCspatial and voxelwise correlation) supported the use of end-tidal CO2 data to extract robust whole-brain CVR maps, despite variability in breath-hold performance. We conclude that the incorporation of end-tidal CO2 monitoring into scanning enables robust, repeatable measurement of CVR that makes breath-hold challenges suitable for routine clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring Vascular Reactivity With Breath-Holds After Stroke: A Method to Aid Interpretation of Group-Level BOLD Signal Changes in Longitudinal fMRI Studies

Blood oxygenation level-dependent (BOLD) contrast functional magnetic resonance imaging (fMRI) is a widely used technique to map brain function, and to monitor its recovery after stroke. Since stroke has a vascular etiology, the neurovascular coupling between cerebral blood flow and neural activity may be altered, resulting in uncertainties when interpreting longitudinal BOLD signal changes. Th...

متن کامل

Agreement and repeatability of vascular reactivity estimates based on a breath-hold task and a resting state scan

FMRI BOLD responses to changes in neural activity are influenced by the reactivity of the vasculature. By complementing a task-related BOLD acquisition with a vascular reactivity measure obtained through breath-holding or hypercapnia, this unwanted variance can be statistically reduced in the BOLD responses of interest. Recently, it has been suggested that vascular reactivity can also be estima...

متن کامل

Robustly accounting for vascular reactivity differences across subjects using breath-hold

Introduction Changes in the BOLD signal associated with neuronal activity reflect increased metabolic demand, cerebral blood flow (CBF) and cerebral blood volume (CBV). Inter-subject differences in local CBF and CBV contribute to differences in BOLD signal reactivity and, therefore, unmodelled variance in group level fMRI analyses. Characterisation of vascular (BOLD signal) responsiveness is of...

متن کامل

Reproducibility of BOLD signal change induced by breath holding

Blood oxygen level dependent (BOLD) contrast is influenced by some physiological factors such as blood flow and blood volume that can be a source of variability in fMRI analysis. Previous studies proposed to use the cerebrovascular response data to normalize or calibrate BOLD maps in order to reduce variability of fMRI data both among brain areas in single subject analysis and across subjects. ...

متن کامل

Fourier modeling of the BOLD response to a breath - hold task : 2 Optimization and

10 Article history: 11 Received 14 October 2015 12 Accepted 12 February 2016 13 Available online xxxx 145678 19 Cerebrovascular reactivity (CVR) reflects the capacity of blood vessels to adjust their caliber in order tomaintain a 20 steady supply of brain perfusion, and itmay provide a sensitive disease biomarker.Measurement of the blood ox21 ygen level dependent (BOLD) response to a hypercapni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 83  شماره 

صفحات  -

تاریخ انتشار 2013