Numerical Deconvolution by a Monte Carlo Approach with Application to Dynamic Cardiac Perfusion Tc-99m SPECT

نویسندگان

  • Koon-Pong Wong
  • Steven R. Meikle
  • David Dagan Feng
  • Michael J. Fulham
چکیده

Accurate determination of the input function is essential for absolute quantification of physiological parameters in PET and SPECT imaging but it requires an invasive and tedious procedure of blood sampling that is impractical in clinical studies. We previously proposed a technique that simultaneously estimates kinetic parameters and the input function from the tissue impulse response functions and which, requires only two blood samples. A nonlinear least squares method was used to estimate all the parameters in the impulse response functions and the input function but it fails occasionally due to high noise levels in the data causing an ill-conditioned cost function. This study investigates the feasibility of applying a Monte Carlo method called simulated annealing to estimate kinetic parameters in the impulse response functions and the input function. Time-activity curves of teboroxime, which is very sensitive to changes in the input function, were simulated based on published data obtained from a canine model. The equations describing the tracer kinetics in different regions were minimised simultaneously by simulated annealing and nonlinear least squares. We found that the physiological parameters obtained with simulated annealing are more accurate and the estimated input function more closely resembled the simulated curve. We conclude that simulated annealing reduces bias in the estimation of physiological parameters and determination of the input function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography

Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-car...

متن کامل

Correlation of myocardial Tc 99m-MIBI perfusion SPECT with coronary angiography in Namazi Hospital/Shiraz/Iran [Persian]

Coronary heart disease (CAD) is the leading cause of death specially among elderly. Coronary angiography is the best diagnostic method in the patients, but is unfortunately an invasive procedure with its inherent risks. Myocardial perfusion scan is a noninvasive and sensitive method for evaluation of CAD and is suggested by many investigators in recent years. In this study, 64 patients wh...

متن کامل

Optimisation of Simultaneous Tl-201/Tc-99m Dual Isotope Reconstruction with Monte-Carlo-Based Scatter Correction

Simultaneous Tl-201/Tc-99m dual isotope myocardial perfusion SPECT is seriously hampered by down-scatter from Tc-99m into the Tl-201 energy window. This paper presents and optimises the ordered-subsets-expectation-maximisation-(OS-EM-) based reconstruction algorithm, which corrects the down-scatter using an efficient Monte Carlo (MC) simulator. The algorithm starts by first reconstructing the T...

متن کامل

Scatter and Cross-Talk Corrections in Simultaneous Tc-99m/I-123 Brain SPECT using Constrained Factor Analysis and Artificial Neural Networks1

Simultaneous imaging of Tc-99m and I-123 would have a high clinical potential in the assessment of brain perfusion (Tc-99m) and neurotransmission (I-123) but is hindered by cross-talk between the two radionuclides. Monte Carlo simulations of 15 different dual-isotope studies were performed using a digital brain phantom. Several physiologic Tc-99m and I-123 uptake patterns were modeled in the br...

متن کامل

Quantitative Nuclear Medicine

09:00 09:25 Coffee and registration 09:25 09:30 Introduction 09:30 10:00 Quantification of the Renogram: Deconvolution and Patlak/Rutland Plot Prof Richard Lawson, Central Manchester Nuclear Medicine Centre, Manchester 10:00 10:30 Improving quantification via multi-modality imaging Prof Brian Hutton, University College London 10:30 11:00 Coffee, Posters and Exhibiton 11:00 11:20 Use of the CT S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001