Experimental and numerical investigation of capillary flow in SU8 and PDMS microchannels with integrated pillars

نویسندگان

  • Auro Ashish Saha
  • Sushanta K. Mitra
  • Jim McLaughlin
چکیده

Microfluidic channels with integrated pillars are fabricated on SU8 and PDMS substrates to understand the capillary flow. Microscope in conjunction with highspeed camera is used to capture the meniscus front movement through these channels for ethanol and isopropyl alcohol, respectively. In parallel, numerical simulations are conducted, using volume of fluid method, to predict the capillary flow through the microchannels with different pillar diameter to height ratio, ranging from 2.19 to 8.75 and pillar diameter to pitch ratio, ranging from 1.44 to 2.6. The pillar size (diameter, pitch and height) and the physical properties of the fluid (surface tension and viscosity) are found to have significant influence on the capillary phenomena in the microchannel. The meniscus displacement is non-uniform due to the presence of pillars and the nonuniformity in meniscus displacement is observed to increase with decrease in pitch to diameter ratio. The surface area to volume ratio is observed to play major roles in the velocity of the capillary meniscus of the devices. The filling speed is observed to change more dramatically under different pillar heights upto 120 lm and the change is slow with further increase in the pillar height. The details pertaining to the fluid distribution (meniscus front shapes) are obtained from the numerical results as well as from experiments. Numerical predictions for meniscus front shapes agree well with the experimental observations for both SU8 and PDMS microchannels. It is observed that the filling time obtained experimentally matches very well with the simulated filling time. The presence of pillars creates uniform meniscus front in the microchannel for both ethanol and isopropyl alcohol. Generalized plots in terms of dimensionless variables are also presented to predict the performance parameters for the design of these microfluidic devices. The flow is observed to have a very low Capillary number, which signifies the relative importance of surface tension to viscous effects in the present study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A NUMERICAL STUDY OF SINGLE-PHASE FORCED CONVECTIVE HEAT TRANSFER WITH FLOW FRICTION IN MICROCHANNELS (RESEARCH NOTE)

Three-dimensional simulations of the single-phase laminar flow and forced convective heat transfer of water in microchannels with small rectangular sections having specific hydraulic diameters and distinct geometric configurations were investigated numerically. The numerical results indicated that the laminar heat transfer was to be dependent upon the aspect ratio and the ratio of the hydraulic...

متن کامل

Capillary driven flow of polydimethylsiloxane in open rectangular microchannels.

The flow of liquid polydimethylsiloxane (PDMS, Dow Corning Sylgard 184, 10 : 1 base to cross-linker ratio) in open, rectangular silicon microchannels, with and without a coating (100 nm) of poly-tetra-fluoro-ethylene (PTFE), was studied. Photolithographic patterning and etching of silicon wafers was used to create microchannels with a range of widths (∼5-50 μm) and depths (5-20 μm). Experimenta...

متن کامل

Embedded MicroHeating Elements in Polymeric MicroChannels for Temperature Control and Fluid Flow Sensing

This paper describes the first demonstration of temperature control and flow sensing of fluids using integrated circuit (IC)-based microheating elements embedded in microchannels molded in polydimethylsiloxane (PDMS). Fluid channels and connections to capillary tubing are molded in PDMS using a silicon wafer template. The PDMS film is then bonded to an IC that contains the micromachined microhe...

متن کامل

Subcooled two-phase flow boiling in a microchannel heat sink: comparison of conventional numerical models

Subcooled flow boiling in multi-microchannels can be used as an efficient thermal management approach in compact electrical devices. Highly subcooled flow boiling of HFE 7100 is studied in two microchannel heat sinks to choose a proper numerical model for simulating boiling flows in microchannels. Results of five different numerical models, including Volume of Fluid (VOF), Eulerian boiling, Eul...

متن کامل

Novel Surface Modification Methods and Surface Property Analysis for Separation of Dna Bio-molecules Using Capillary Electrophoresis

This paper presents systematic investigation on the surface properties of electroosmotic flows (EOF) inside microchannels for quartz, glass and PDMS based materials. Two novel methods to modify the surface properties of glass-based microchannels for capillary electrophoresis (CE) are developed. Instead of using complicated and time-consuming chemical silanization procedures for surface modifica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008