Balancing radiation dose and image quality: clinical applications of neck volume CT.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The advancement of multidetector CT technology has resulted in improved image quality as well as an increase in ionizing radiation dose to patient. The purpose of this study was to assess radiation dose and overall image quality of CT examination of the neck between fixed-tube current and automatic tube current modulation (ATCM) at 2 separate noise index levels. MATERIALS AND METHODS A total of 84 patients underwent neck CT with use of a 64-section multidetector row CT (MDCT) scanner. Patients were divided into 3 groups: fixed-tube current (n = 28), ATCM with a noise index of 11.4 (n = 28), and ATCM with a noise index of 20.2 (n = 28). All other scan parameters remained constant. Scan coverage length and transclavicular distance were measured. Two radiologists blinded to the scanning parameters assessed overall image quality, noise level, and streak artifacts using a 5-point grading scale. The radiation dose in dose-length product (DLP) and CT dose index (CTDI) was recorded. RESULTS Compared with a fixed-tube current technique, ATCM with a noise index of 11.4 reduced CTDI by 20% (P < .01 x 10(-6)), and ATCM with a noise index of 20.2 reduced CTDI by 34% (P < .01 x 10(-12)). Although the difference in image quality between the fixed-tube current technique and the noise index reached statistical significance (P < .05), the magnitude of the difference was small, with average scores of 3.79 (+/-0.59) and 3.57 (+/-0.53), respectively. CONCLUSION Compared with the fixed-tube current technique, ATCM resulted in significant reduction of radiation dose without substantially reducing the image quality of the CT of the neck. Judicious monitoring of radiation dose to patients has to be balanced with diagnostic image quality.
منابع مشابه
Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملMetal Artifact Reduction of Dental Fillings in Head and Neck CT Images
Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...
متن کاملThyroid dose and dose reduction method from CT scan of head and neck
Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...
متن کاملInvestigating the effects of different kernels used for CT image reconstruction on dose distributions in treatment planning of kidney cancer radiotherapy
Introduction: The quality of CT images used for treatment planning of cancer patients is an important issue in accurate outlining of the tumor volume and organs at risk. Different kernels in CT scanner systems are available for improving the image quality. Applying these kernels on CT images will change the CT numbers and electron density of tissues, conse...
متن کاملStrategy of computed tomography image optimization in cervical vertebra and neck soft tissue in emergency patients
Introduction: Due to the use of ionizing radiation in the CT scan, optimal parameters should be used to reduce the risk of cancer in patients who are constantly exposed to X-rays. The aim of this study was to optimize the parameters used in CT scan of cervical vertebrae and neck soft tissue with minimal loss of image quality Materials and Methods: In this s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 29 4 شماره
صفحات -
تاریخ انتشار 2008