Ultrasound biomicroscopic measurement of development of anterior chamber angle.

نویسندگان

  • H Kobayashi
  • H Ono
  • J Kiryu
  • K Kobayashi
  • T Kondo
چکیده

AIM To establish normative values for the anterior segment in normal infants and children in relation to age. METHODS Anterior segments were measured in 46 normal infants and children (21 males and 25 females, aged from 1 to 60 months (mean 17.09 (SD 16.99) months)), by use of ultrasound biomicroscopy. RESULTS Anterior chamber depth, trabecular-iris angle, angle opening (trabecular-iris) distances at 250 and 500 microm from the scleral spur, and the thickness of the thickest part of the iris were 1724-3473 microm (2505 (SD 480) microm), 15.35-44.79 degrees (28.74 (7.46) degrees ), 116-367 microm (247.4 (65.9) microm), 166-509 microm (349.5 (87.1) microm), and 249-579 microm (434.6 (74.6) microm), respectively. All factors in this study showed a significant correlation with logarithm of age (r = 0.937, p = 0. 0001; r = 0.867, p = 0.0001; r = 0.929, p = 0.0001; r = 0.917, p = 0. 0001; r = 0.748, p = 0.0001), and significantly correlated with each other. CONCLUSIONS Ultrasound biomicroscopy is a powerful tool for obtaining precise images and measurement of the development of the anterior segment in infants and children. Normative values were established for anterior segment dimensions in relation to age. Anterior chamber depth, trabecular-iris angle, angle opening distances at 250 and 500 microm from the scleral spur, and iris thickness showed linear increases in relation to logarithm of age.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel approach for anterior chamber angle analysis: anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA).

OBJECTIVE To describe a novel approach to measuring anterior chamber angle dimensions and configurations. METHODS Sixty-nine images were selected randomly from the ultrasound biomicroscopic image database to develop the algorithm. Thirty images were selected for further analyses. The value of each pixel of the 8-bit grayscale ultrasound biomicroscopic images was quantized into 0 (black) or 1 ...

متن کامل

Ultrasound biomicroscopic measurement of anterior chamber angle in premature infants.

AIM To establish normative values for the anterior segment in premature infants in relation to postconceptional age and birth weight. METHODS Anterior segments were measured in 39 premature infants, 25 to 39 weeks' gestational age by use of ultrasound biomicroscopy and a muscle hook with topical anaesthesia. RESULTS Anterior chamber depth, trabecular-iris angle, angle opening (trabecular-ir...

متن کامل

Ultrasound biomicroscopic measurement of anterior chamber biometry between before and after pupil dilation in children.

PURPOSE To evaluate anterior chamber biometry of the eyes of normal children using ultrasound biomicroscopy (UBM) and to evaluate the differences in biometry between children and adults, and before and after pupil dilation in children. METHODS Anterior chamber depth (ACD) and trabecular-iris angle (TIA) were measured in 94 normal children and 15 normal adults using UBM. Before and after pupil...

متن کامل

Ultrasound biomicroscopic analysis of pseudophakic pupillary block glaucoma induced by Soemmering's ring.

AIM To perform ultrasound biomicroscopic analysis of pseudophakic pupillary block glaucoma induced by lens capsule and a Soemmering's ring and its resolution, and to elucidate the pathophysiology of this glaucoma. METHODS A woman with pseudophakic pupillary block glaucoma underwent successful neodymium:YAG (Nd:YAG) laser photodisruption of the lens capsule through a laser iridotomised colobom...

متن کامل

Pseudophakic angle-closure from a Soemmering ring

BACKGROUND Report of three patients with pseudophakic angle-closure from a Soemmering ring. Three mechanisms of the Soemmering ring induced pseudophakic angle-closure in three patients were demonstrated by meticulous anterior segment examination and ultrasound biomicroscopic (UBM) analysis. CASE PRESENTATION In the first case, the Soemmering-capsule-IOL complex caused relative pupillary block...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 83 5  شماره 

صفحات  -

تاریخ انتشار 1999